Grizzly G0572 Manuale Utente

Pagina di 32
-16-
G0572 Hanging Air Filter with Remote
Figure 8. Rubber feet correctly installed
(Underside View).
Note— For  permanent  table-top  mounting,  refer 
to  the  Flush  Mount  procedure  on 
Page  17,  and 
install  the  air  filter  unit  to  the  tabletop  with  the 
flush mount flange brackets.
Hanging Mount
3.  Repeat Step 2 for remaining feet.
Components and Hardware Needed 
Qty
Eye bolts  ........................................................... 4
Chain, cable, or steel strapping lines  ............... 4
Tools Needed
Wrench 12mm  ...................................................1
To make the unit operate at the optimum height 
of  7'  from  the  floor,  you  can  install  the  air  filter 
unit in your shop by hanging it by chain, cable, or 
steel strapping.
Flange Bracket Mounting 
Holes
 Rubber Feet
ONLY hang the air filter to load bearing ceil-
ing studs or joists that can hold at least 100 
lbs. DO NOT mount the unit to sheet rock, 
pressboard,  paneling,  or  honeycomb  ceil-
ing  panels  with  expansion-type  fasteners 
like the ones shown in Figure 9. The fasten-
ers  can  tear  out  and  the  air  filter  can  fall. 
Ignoring  this  warning  can  result  in  severe 
injury or death.
To  install  the  air  filter  for  hanging  mount 
operations:
1.  Install  four  chain,  cable,  or  steel  strapping 
lines to your ceiling from capable ceiling joists 
or supports. When the lines hang down freely 
they  should  be  15
1
4
"  from  left-to-right  and 
24
1
2
"  from  front-to-rear.  Optimally,  the  unit 
should hang 7' off the floor when finished. 
Figure 9. Typical unacceptable fasteners.
Get  lifting  assistance 
before    installation.  At 
64  pounds  (shipping 
weight), the Model G0572 
air filter is a heavy load.