Grizzly G0572 Manuale Utente

Pagina di 32
G0572 Hanging Air Filter with Remote
-25-
Disconnect power to the 
machine  when  perform-
ing  any  troubleshooting. 
Failure  to  do  this  may 
result in serious person-
al injury.
Symptom
Possible Cause
Possible Solution
The air filter does not operate at all.
1.  The power supply circuit breaker is  
tripped. 
2.  No power to the control panel
3.  Wiring is at fault
4.  The  control  panel  circuit  board  is  at  
fault.
5.  The motor is at fault. 
1.  Correct  the  cause  for  high  current 
draw and close the circuit breaker.
2.  Replace the blown fuse in the control  
panel. 
3.  Repair,  replace  wires,  plugs  and 
cables  as  applicable;  and  make  sure 
all  electrical  plugs  and  connections 
are secure.
4.  Replace the circuit board. 
5.  Replace the motor.
The remote control does not operate the 
air  filter  but  the  control  panel  operates 
fine.
1.  The remote control has no power.
2.  The signal path is obstructed.
3.  The remote control is at fault.
4.  The  control  panel  circuit  board  is  at 
fault. 
1.  Install or replace the batteries.
2.  Make  sure  the  signal  path  is  clear  to 
the infrared remote control sensor on 
the control panel.
3.  Replace the hand-held remote control 
unit. 
4.  Replace  the  control  panel  circuit 
board. 
The air filter CFM output is reduced.
1.  The filters are wet or clogged. 
2.  The airflow path is obstructed.
3.  The control panel circuit board is at  
fault. 
4.  The motor is at fault. 
1.  Replace  the  primary  filter  and  clean 
the secondary filter. 
2.  Remove obstructions or add ducting.
3.  Replace  the  control  panel  circuit 
board.
4.  Replace the motor.
The air filter unit is noisy or vibrates.
1.  The mounting is loose.
2.  The unit is not level.
3.  The fan or motor is loose.
1.  Tighten  the  flange  brackets  and  rein-
stall the air filter unit. 
2.  Level the air filter unit. 
3.  Unplug the unit, remove the filters, and 
tighten all loose fastners.
Troubleshooting