Amana *D(H Manuale Utente

Pagina di 48
32
O
PERATIONAL
 C
HECKS
 & S
AFETY
 C
IRCUIT
 D
ESCRIPTION
R
OLLOUT
 L
IMITS
The rollout limit controls are mounted on the burner/manifold
assembly and monitor the burner flame.  They are   manual-
reset, temperature sensors.  This limit guards against burner
flames not being properly drawn into the heat exchanger.
P
RESSURE
 S
WITCHES
The pressure switches are normally-open, negative air pres-
sure-activated switches.  They monitor the airflow (combustion
air and flue products) through the heat exchanger via pressure
taps located on the induced draft blower.  These switches guard
against insufficient airflow (combustion air and flue products)
through the heat exchanger.
F
LAME
 S
ENSOR
The flame sensor is a probe mounted to the burner/manifold
assembly which uses the principle of flame rectification to de-
termine the presence or absence of flame.
T
ROUBLESHOOTING
E
LECTROSTATIC
 D
ISCHARGE
 (ESD) P
RECAUTIONS
NOTE:  Discharge body’s static electricity before touching unit.
An electrostatic discharge can adversely affect electrical
components.
Use the following precautions during furnace installation and
servicing to protect the integrated control module from dam-
age.  By putting the furnace, the control, and the person at the
same electrostatic potential, these steps will help avoid expos-
ing the integrated control module to electrostatic discharge.
This procedure is applicable to both installed and uninstalled
(ungrounded) furnaces.
1. Disconnect all power to the furnace.  Do not touch the
integrated control module or any wire connected to the
control prior  to discharging your body’s electrostatic
charge to ground.
2. Firmly touch a clean, unpainted, metal surface of the
furnace away from the control.  Any tools held in a
person’s hand during grounding will be discharged.
3. Service integrated control module or connecting wiring
following the discharge process in step 2.  Use caution
not to recharge your body with static electricity; (i.e., do
not move or shuffle your feet, do not touch ungrounded
objects, etc.).  If you come in contact with an ungrounded
object, repeat step 2 before touching control or wires.
4. Discharge your body to ground before removing a new
control from its container.  Follow steps 1 through 3 if
installing the control on a furnace.  Return any old or
new controls to their containers before touching any
ungrounded object.
D
IAGNOSTIC
 C
HART
Refer to the troubleshooting chart in the Appendix for assis-
tance in determining the source of unit operational problems.
The red diagnostic LED blinks to assist in troubleshooting the
unit.  The number of blinks refer to a specific code.
NOTE: To clear all alarm codes, depress the push button for 6
seconds.
F
AULT
 R
ECALL
The ignition control is equipped with a momentary push button
switch that can be used to display on the diagnostic LED the
last five faults detected by the control. The control must be in
Standby Mode (no thermostat inputs) to use the feature. De-
press the pushbutton switch for approximately 2 seconds. Re-
lease the switch when the LED is turned off. The diagnostic
LED will then display the flash codes associated with the last
five detected faults. The order of display is the most recent fault
to the least recent fault.
R
ESETTING
 F
ROM
 L
OCKOUT
Furnace lockout results when a furnace is unable to achieve
ignition after three attempts.  It is characterized by a non-func-
tioning furnace and a one flash diagnostic LED code from the
red LED.  If the furnace is in “lockout”, it will (or can be) reset in
any of the following ways.
1. Automatic reset.  The integrated control module will
automatically reset itself and attempt to resume normal
operations following a one hour lockout period.
2. Manual power interruption.  Interrupt 115 volt power to
the furnace for 1 - 20 seconds.
3. Manual thermostat cycle.  Lower the thermostat so that
there is no longer a call for heat for 1 - 20 seconds then
reset to previous setting.
NOTE:  If the condition which originally caused the lockout still
exists, the control will return to lockout.  Refer to the Diagnostic
Chart for aid in determining the cause.
M
AINTENANCE
T
O
 
AVOID
 
ELECTRICAL
 
SHOCK
INJURY
 
OR
 
DEATH
DISCONNECT
 
ELECTRICAL
 
POWER
 
BEFORE
 
PERFORMING
 
ANY
 
MAINTENANCE
. I
F
 
YOU
 
MUST
 
HANDLE
 
THE
 
IGNITER
HANDLE
 
WITH
 
CARE
. T
OUCHING
 
THE
 
IGNITER
 
ELEMENT
 
WITH
 
BARE
 
FINGERS
ROUGH
 
HANDLING
OR
 
VIBRATION
 
COULD
 
DAMAGE
 
THE
 
IGNITER
 
RESULTING
 
IN
 
PREMATURE
 
FAILURE
. O
NLY
 
A
 
QUALIFIED
 
SERVICER
 
SHOULD
 
EVER
 
HANDLE
 
THE
 
IGNITER
.
WARNING