Vermont Casting DEF33 Manuale Utente

Pagina di 16
5
10005898
Vermont Castings, Majestic Products, DEF33/36, DEFD33/ 36
Mantels
The height that a combustible mantel is fitted above
the fireplace is dependent on the depth of the mantel.
This also applies to the distance between the mantel
leg (if fitted) and the fireplace.
For the correct mounting height and widths, refer to
Figures 2a, 2b and the Mantel Chart below.
The distances and reference points are not affected by
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the
mantel, such paint or lacquer must be
heat resistant to prevent discoloration.
J
F
G
H
I
Mantel
Leg
Black
Surround
Face
CFM164a
O
N
M
L
K
Side of
Combustion
Chamber
CFM170
Fig. 2b  Combustible mantel leg minimum installation
Mantel
Mantel Leg from Side
Ref.
Leg Depth
Ref.
of Comb. Opening
F
10” (254mm)
K
11
¹⁄₂
” (292mm)
G
8” (203mm)
L
9
¹⁄₂
” (241mm)
H
6” (152mm)
M
7
¹⁄₂
” (191mm)
I
4” (101mm)
N
5
¹⁄₂
” (140mm)
J
2” (50mm)
O
3
¹⁄₂
’” (89mm)
Mantel Chart
Mantel Shelf
Mantel from Top
Ref. or Breast Plate Ref.    of Comb. Chamber
Depth
DEF33
DEF36
V
10” (254
 
mm)
A
17" (432 mm) 19" (483 mm)
W
8” (203
 
mm)
B
15" (381 mm) 17" (432 mm)
X
6” (152 mm)
C
13" (330 mm) 15" (381 mm)
Y
4” (101 mm)
D
11" (279 mm) 13" (330 mm)
Z
2” (50 mm)
E
9" (229 mm)
11" (279 mm)
A
B
C
D
E
V
W
X
Y
Z
Fireplace
Top Louvre
Opening
Top of Combus-
tion Chamber
Bottom of Door Trim
CFM146
Fig. 2a   Combustible mantel minimum installation