Vermont Casting 2100 Manuale Utente

Pagina di 44
20
WinterWarm Fireplace Insert or System
2000941
FP1087
WW
Flex connector
3/30/01   djt
Flex Connector
1/4” (6mm) 
Nut
Pipe 
Support
1/4” (6mm) 
Nut
Pipe 
Support
Block-Off 
Plate
1/4” 
(6mm) 
Screw
Starter Piece 
(Optional)
1/4” 
(6mm) 
Wing Nut
1/4” (6mm) 
Washer
1/4” (6mm) Bolt
FP1087
Fig. 22  Components of the Flex Connector System.
Consult a Vermont Castings’ Authorized Dealer for in-
stallation suggestions. It may be possible to enlarge the 
opening by removing or modifying the damper frame, 
but do this only if it won’t weaken the fireplace.  Check 
with your local building inspector to be sure modifica-
tions comply with local codes.
Although the Flex Connector is designed to be installed 
by any mechanically competent person, wide variations 
in fireplace and damper construction can complicate 
the installation. You may wish to have the job done 
by a professional installer. Complete detailed installa-
tion instructions are included with the Flex Connector 
components.
A Custom Damper Seal
If the design of your fireplace damper prohibits the use 
of the CFM Corporation Sealing Package, an alterna-
tive is to fabricate a custom sealing plate at or below 
the fireplace damper frame. The plate can be fastened 
securely to the lintel (the structural piece spanning the 
fireplace opening) and to the surrounding masonry, or 
be securely fastened to the damper frame. A section 
of chimney connector, attached to the WinterWarm 
flue collar, must make a positive flue connection where 
required by code. 
A Relined Chimney
There are a number of fittings available from your Ver-
mont Castings’ Authorized Dealer that are designed to 
form the connection between your WinterWarm and an 
8” (203mm) diameter chimney liner. Your dealer as well 
as your local chimney sweep can advise you on the 
types of lining systems currently available.
Preliminary Steps for Installing the 
WinterWarm into a Masonry Fireplace
1. Remove the Masonry Fireplace Damper
The existing damper plate within your fireplace must 
be removed or, if that is not possible, must be fastened 
securely in a fully-open position.  Many dampers can 
be removed simply by removing a cotter pin and/or set 
screw.
2. Install the Flex Connector
Following the installation instructions that are packed 
with the Flex Connector, unfold the template that came 
with the WinterWarm. (Fig. 23) Carefully glue the tem-
plate onto a large piece of sturdy cardboard or plywood, 
making sure that the fold lines have been flattened.  Cut 
along the edges of the template and use it to place the 
Flex Connector components correctly in your fireplace.  
Custom Fabrication:
Be sure any chimney connector or adapter is properly 
installed and secured in place.  There should be a slip 
joint near the WinterWarm so that the connection can 
be easily disengaged for removal and cleaning of the 
unit.
FP1088
WinterWarm
template
3/30/01   djt
Template
FP1088
Fig. 23  Using the template that came with the WinterWarm 
will help you position Flex Connector.