Lennox Hearth MPD-4540CNM-B Manuale Utente

Pagina di 42
24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
LENNOX HEARTH PRODUCTS  •  MERIT
®
 PLUS DIRECT VENT GAS FIREPLACES (MPD33/35/40/45)  •  INSTALLATION INSTRUCTIONS
5" (127 mm)
Radius Minimum
Flexible Vent Section
E. Attach Flex Vent to Termination -  
Secure Flex components can be purchased 
separately  and  attached  to  bulk  lengths  of 
Secure Flex flexible tubing cut to size at the 
job site.   Secure the flexible vent to the Secure 
Flex  terminations  in  the  same  manner  (see 
Figure 45 as it was attached to the adapter.
See the appropriate sections and figures shown 
throughout the venting section for their instal-
lation requirments. 
Note:  Secure  Flex  vent  must  be  attached 
to Secure Flex terminations only.  dO NOT 
substitute Secure Vent terminations or the 
Secure Vent adapter for Secure Flex compo-
nents. The collars of Secure Flex terminations 
and adapters have a different circumference 
than  that  used  with  the  Secure  Vent  pipe.  
Additionally, Secure Flex components have 
an  extended  length  center  tube  for  use  in 
attaching the flexible vent.
Figure 46 
VERTICAL OR HORIZONTAL VENTING USING 
SECuRE FlEx
 KITS ANd COMPONENTS
Secure Flex venting kits and components may 
be used in any venting application where rigid 
Secure Vent (SV4.5) direct vent components 
can be used.  All restrictions, clearances and 
allowances that pertain to the rigid piping apply 
to the flexible venting.  Secure Flex kits may 
not be modified; also, under no circumstances 
may separate sections of flex pipe  be joined 
together.  Secure  Flex  kits  may  be  added  to 
the end of a vent run made up of rigid Secure 
Vent (SV4.5) vent sections provided that doing 
so does not violate any of the venting length, 
height, routing, horizontal to vertical ratio re-
quirements or clearance considerations detailed 
in this manual.
Secure Flex kits come with an included adapter 
that can be fitted to the appliance collar or the 
inclined channel end of the last Secure Vent 
(SV4.5) vent section in a rigid system in the 
exact same fashion as any other Secure Vent 
section.  Align the dimpled end of the adapter 
over the previously installed section or appliance 
collar, adjusting the radial alignment until the 
four locking dimples of the adapter are aligned 
with the inlets of the four incline channels of 
the  last  vent  section  or  collar.    Push  on  the 
adapter  until  it  fully  engages,  then  twist  the 
adapter clockwise running the dimples down 
and along the incline channels until they seat 
at the end of the channels.
Attach the flexible vent to the adapter as fol-
lows (see Figure 45):
A. Install the Inner Flex Pipe - 
1. Install the small  gear clamp loosely around 
the inner flexible vent pipe, push it back out 
of the way.
2.  Apply a bead of Mill-Pac Black (700°F) high 
temperature sealant - Catalog No. 10K81) to 
the inner adapter collar, approximately 1/2 inch 
from the end.
3. Pull and extend the inner flexible vent pipe. 
4.  Slide the inner flex pipe over the adapter 
collar. Ensure the flexible vent pipe completely 
engages  the  adapter  collar  to  a  distance  of 
1-3/4  inches from the end, and that it is free 
from damage or tears. 
 5.  Slide the gear clamp down and tighten it 
fully to secure the flexible vent to the adapter 
inner collar approximately 3/4 inch from the 
end of the flex.
6.  Install  three  screws  120  degrees  apart 
through  the  flexible  vent  pipe  and  into  the 
adapter  collar  just  below  the  gear  clamp  to 
provide additional security to the connection.
B. Install the Outer Flex Pipe - 
1. Install the large gear clamp loosely around 
the outer flexible vent pipe, push it back out 
of the way. 
2.  Apply a bead of Mill-Pac Black (700°F) high 
temperature sealant - Catalog No. 10K81) to 
the outer adapter collar; to the grooves of the 
collar which extend approximately 1 inch from 
the end and to the flat surface, approximately 
1-3/8 inches from the end. 
3. Pull and extend the outer flexible vent pipe. 
4.  Slide the outer flex pipe over the adapter 
collar. Ensure the flexible vent pipe completely 
engages the adapter collar to a distance of 1³⁄₄ 
inches from the end, and that it is free from 
damage or tears. 
5.  Slide the gear clamp down and tighten it 
fully to secure the flexible vent to the adapter 
outer collar approximately 3/4 inch from the 
end of the flex.
6.  Install  three  screws  120  degrees  apart 
through  the  flexible  vent  pipe  and  into  the 
adapter  collar  just  below  the  gear  clamp  to 
provide additional security to the connection.
C. Route Flex Vent -   
Ensure that the flex vent is properly routed to 
provide the required clearance.  Do Not allow 
the flexible vent to bend in a radius tighter than 
5"  (127  mm).    Refer  to  Figure  46.  Support 
horizontal sections of flex with metal straps at 
2 foot (0.61 m) intervals. 
d. Install Firestop/Spacers at ceilings and walls -   
When Secure Flex penetrates a wall or ceiling, 
a firestop/spacer is required: use the SF4.5 VF 
firestop/spacer for ceilings and the SF4.5 HF 
firestop/spacer for walls. 
GEAR
CLAMPS
Adapter
(SV4.5RF)
Apply  ONLY  MIL-PAC  BLACK  HIGH
TEMPERATURE SEALANT (Catalog No.
10K81) to the outside surface of both
collars of the adapter (be especially
careful to fill the grooves of the outer
collar to be covered by the flexible
pipe)  and  slide  flexible  pipe  over
inner  and  outer  adapter  collars.
NOTE:  OUTER PIPE IS PULLED AWAY TO
SHOW THE DETAIL OF THE INNER PIPE
FLEX VENT
1-3/4 in. (44 mm)
Flexible Pipe and
 Adapter Outer
Collar Overlap
1-3/4 in. (44 mm)
Flexible Pipe and
 Adapter Inner
Collar Overlap
SECURING SCREW
(3 PLACES EQUALLY SPACED
JUST BELOW GEAR CLAMP)
Attach Adapter to Appliance
Collar, or Secure Vent Sections
SECURING SCREW
(3 PLACES EQUALLY SPACED
JUST BELOW GEAR CLAMP)
Figure 45