The Top Facing Support, the Side Nailing Strips 
and the 2 Top Standoffs must be correctly 
positioned and attached to the top before the 
unit is put into position. 
Top Standoff Assembly
The top standoffs are shipped in a fl at position 
and must be pulled up and bent into the correct 
shape.
1)  Remove the standoffs from on top of the 
fi rebox by undoing the screws.
2)  Take each standoff and bend into the correct 
shape. Bend up at the bend lines until the 
screw holes in the standoff and the pre-
punched screw holes on the fi rebox top 
line-up.
3)  Attach the standoffs securely to the top with 
4 screws per standoff.
 
Note:  Secure the standoffs to the holes 
closest to the edge of the fi rebox top.
Top Facing Support &
Side Nailing Strips
Determine the total thickness of facing material 
(e.g. drywall plus ceramic tiles) to allow the 
fi nished surface to be fl ush with the front of the 
unit. Total facing thickness can vary from 1/2" 
(13mm) to 1-1/4" (32mm) thick. 
The Top Facing Support & Side Nailing Strips 
can be mounted in various positions depending 
on the thickness of the facing material.
1)  Mount Top Facing Support using the 3 
supplied screws into the three pre-punched 
screw holes on the top front of the unit. Adjust 
support to desired facing material depth.
2)  Mount Side Nailing Strip using the 3 
supplied screws into the three pre-punched 
screw holes at the front sides of the unit. 
Adjust support to desired facing material 
thickness.
UNIT ASSEMBLY PRIOR TO INSTALLATION
INSTALLATION
VENTING INTRODUCTION
The  P33-4  uses  the  "balanced  fl ue"  technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer 
liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing 
warm room air up the chimney.
There are 5 vent systems approved for use with the P33-4: the Regency
®
 Direct Vent Flex System for Horizontal Terminations only and the Simpson 
Dura-Vent, Selkirk Direct-Temp, Amerivent Direct Vent and Security Secure Vent Systems for Horizontal and Vertical Terminations (see following 
"Venting" Sections for more details).
Note: These 
fl ue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate 
solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited. 
(See "Rigid Pipe Venting System" for more details and exceptions).
NOTE: Ensure compliance with the outside vent terminal location before cutting hole as both dimensions must be met.
For a facing material depth of 
1-1/4"(32mm), the top facing 
support must be reversed.