Regency P33-LP4 Manuale Utente

Pagina di 52
Regency
®
 P33-4 Zero Clearance Direct Vent Gas Fireplace
42
AERATION 
ADJUSTMENT
The air shutter can be adjusted by moving the 
adjusting wire up or down. The wire is accessed 
through the bottom louver opening. Open 
the air shutter for a blue fl ame or close for a 
yellower fl ame. The burner aeration is factory 
set but may need adjusting due to either the 
local gas supply or altitude. 
Minimum Air Shutter Opening: 
 3/16" 
Natural 
Gas
 3/8" 
Propane
CAUTION: Carbon will be produced if air 
shutter is closed too much. 
OPERATING INSTRUCTIONS
should continue to burn. If the pilot does not 
remain lit, repeat operation allowing a longer 
period before releasing gas control knob.
4)  When the pilot stays lit, turn the gas knob 
further counterclockwise to the "ON" 
position.
5)  Use the wall switch, thermostat or remote 
control to turn on the unit.
6)  Rotate the fl ame height regulator to adjust 
the fl ame height higher or lower.
SHUTDOWN 
PROCEDURE
1)  Use the wall switch, thermostat or remote 
control to turn off the main burner.
2)  Turn the main gas control clockwise to the 
"OFF" position to turn off the pilot.
3)  Turn off all electric power to appliance if 
service is to be performed. 
FIRST FIRE
The fi rst fi re in your fi replace is part of the 
paint curing process. To ensure that the paint 
is properly cured, it is recommended that you 
burn your fi replace for at least four (4) hours the 
fi rst time you use it with the fan on. 
When fi rst operated, the unit will release an odour 
caused by the curing of the paint, the burning 
off of any oils remaining from manufacturing. 
Smoke detectors in the house may go off at this 
time. Open a few windows to ventilate the room 
for a couple of hours. 
The glass panel may require cleaning after the 
unit has cooled down.  DO NOT ATTEMPT TO 
CLEAN THE GLASS WHILE IT IS HOT. 
Note: When the glass is cold and the 
appliance is lit, it may cause 
condensation and fog the glass. 
This condensation is normal and will 
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed.
5)  Verify that the venting and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
LIGHTING PROCEDURE
IMPORTANT: Gas on/off knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
1)  Turn burner OFF using "ON/OFF" switch.
2)  Turn gas control knob so indicator points 
to "OFF" position and allow 5 minutes for 
any gas in the combustion chamber to 
escape.
3)  Turn gas control knob counterclockwise 
so indicator points to the "PILOT" position. 
Depress the gas control knob fully. Depress 
the igniter button several times until the 
pilot lights. After approximately one minute, 
release the gas control knob. The pilot fl ame 
Closed - Tall yellow
Open - Short blue
Note:   Any  damage due to carboning 
resulting from improperly setting 
the aeration controls is NOT covered 
under warranty.
Note:  Aeration Adjustment should only 
be performed by an authorized 
Regency
®
 Installer at the time of 
installation or service.
Adjustment Wire: push to close
or pull to open aeration cap
wire
Air
shutter
disappear in a few minutes as the 
glass heats up.
DO NOT BURN THE APPLIANCE 
WITHOUT THE GLASS FRONT IN 
PLACE.
IMPORTANT
To ignite or reignite the pilot, 
you must fi rst release the ten-
sion springs below the door. 
Only when the pilot holds, without pressure  
being applied to the control knob, reapply the 
tension springs to the door. The unit must 
not
 be operated with the tension springs 
unattached. 
NOTE: For all propane units and units    
equipped with electric spark boxes, 
see "Copy of Lighting Plate Instruc-
tions" section for more details.
During the fi rst few fi res, a white fi lm 
may develop on the glass front as part 
of the curing process. The glass should 
be cleaned or the fi lm will bake on and 
become very diffi cult to remove. Use a 
non-abrasive cleaner and NEVER clean 
the glass while it is hot.