 G36D Zero Clearance Direct Vent Gas Fireplace
9
"C" Screw Position:
For a facing material depth of 1-1/4" 
(32mm), the top facing support must be 
reversed.
UNIT ASSEMBLY 
PRIOR TO 
INSTALLATION
The Top Facing Support, the Side Nailing Strips 
and  the  2  Top  Standoffs  must  be  correctly 
positioned and attached to the top before unit 
is slipped into position. 
Top Standoff Assembly
The top standoffs are shipped in a fl at position 
and must be folded into shape and attached.
1)  Remove  the  standoffs  from  the  fi replace 
top.
2)  Take each standoff and bend into the correct 
shape. Bend up at the bend lines until the 
screw  holes  in  the  standoff  and  the  pre-
punched screw holes on the fi replace  top 
line up. 
Top Facing Support and 
Side Nailing Strips
Determine the total thickness of facing material 
(e.g.  drywall  plus  ceramic  tiles)  to  allow  the 
fi nished surface to be fl ush with the front of the 
unit. Total facing thickness can vary from 1/2" 
(13mm) to 1-1/4" (32mm) thick. 
The Top Facing Support & Side Nailing Strips can 
be mounted in 3 different positions depending 
on the thickness of the facing material.
* For "C" screw position the top facing support 
is reversed.
1)  Mount  Top  Facing  Support  using  the  3 
supplied screws into the three pre-punched 
screw holes on the top front of the unit. Use 
hole positions A, B, or C depending on your 
facing depth.
2)  Use the same screw hole position for the 
Side Nailing Strips as was used for the Top 
Facing  Support. Attach  each  side  nailing 
strip using 3 screws.
VENTING 
INTRODUCTION
The  G36D  uses  the  "balanced  fl ue"  technology 
Co-Axial system. The inner liner vents products 
of combustion to the outside while the outer liner 
draws outside combustion air into the combustion 
chamber thereby eliminating  the need to use 
heated room air for combustion and losing warm 
room air up the chimney.
Note:  These  flue  pipes  must  not  be 
connected to any other appliance.
The  gas  appliance  and  vent  system  must  be 
vented  directly  to  the  outside  of  the  building, 
and never be attached to a chimney serving a 
separate  solid  fuel  or  gas  burning  appliance. 
Each direct vent gas appliance must use it's own 
separate vent system. Common vent systems 
are prohibited.
17-1/8"
3-1/2"
4"
2"
40-1/2"
37
32-1/2"
10" dia. hole
through wall
for Flex
or for DuraVent
1/2"
Drywall
Top Header
Opening for gas
connection
Note:  40-1/2"  (1029mm)  is  the  minimum 
height  for  both  fl ex  termination  or 
Simpson Dura-Vent venting.
5)  The unit does not have to be completely 
enclosed  in  a  chase.  The    clearance  on 
top  of  the  unit  is  0"  to  the  standoffs  so 
combustible  building  materials  can  be 
laid  directly  on  top  of  the  standoffs.  You 
must maintain  clearance from the vent to 
combustible materials for fl ex, see section 
"Clearances."
6)  Use steel studs for framing where the 
 
1-1/2" (38mm) clearance from the vent to 
combustible material cannot be maintained, 
e.g. front top header.
INSTALLATION
3)  Attach  the  standoff  securely  to  the  top 
with  2  screws  per  standoff  (on  opposite 
corners).
Screw 
Facing Material 
Position 
Depth
1/2" 
/ 13mm
7/8" 
/ 22mm
C
* 
1-1/4" 
/ 32mm
Screw 
Facing Material 
Position 
Depth
1/2" 
/ 13mm
7/8" 
/ 22mm
 
1-1/4" 
/ 32mm