REMINGTON QFP40 Direct Vent FIREPLACE
250-4721   JUNE 2001
Install fireplace in accordance with all local codes, if any; if none, follow The National Fuel Gas
Codes ANSI Z223.1-1992 and NFPA 54(88); or Canadian Installation Codes CAN/CGA-B149.
Manufactured or Mobile Home Installation   This appliance is only for use with the type of gas indi-
cated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mo-
bile) home where not prohibited by local codes.  Installations must conform with: USA:   Manufactured
Home Construction and Safety Standard,  Title 24 CFR, Part 3280.  CANADA: CSA Z240.4 and Gas-
Equipped Recreational Vehicles and Mobile Housing.
MODEL:  REMINGTON QFP40
VENTED GAS FIREPLACE HEATER
 NOT FOR USE WITH SOLID FUEL - NOT FOR USE WITH AIR FILTERS
         The “Remington QFP40” is factory equipped for natural gas (NG)  and is field convertible to pro-
pane  gas  (LP),  when  equipped  with  the  Conversion  Kit  #842-4470  available  from  an Aladdin  Hearth
Products  dealer.   This  appliance  uses  a  millivolt-type  control  system  consisting  of  a  gas  control  valve/
regulator, a standing pilot burner assembly, a thermopile, a piezo ignitor, and the ON/OFF switch.  THIS
UNIT  DOES  NOT  REQUIRE  110  VOLT  POWER  TO  OPERATE.   All  exhaust  gases  must  be  vented
outside the structure of the living area.  Combustion air is drawn from outside the living area structure.
WARNINGS:
This appliance should be inspected before use and at least annually by a qualified service person.  More
frequent cleaning may be required where excessive lint from material like carpeting and bedding is present.
The control compartment, the burner compartment and all circulating air passageways of the appliance
must be kept clean and clear at all times.  Due to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.  This appliance must not be connected to a chimney flue
servicing a separate solid fuel burning appliance.  Children and adults should be alerted to the hazards of
high surface temperature and should stay away to avoid flesh burns or clothing ignition.  Young children
should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:   All safety screen or guard components removed for servicing, must be replaced prior to
operating the appliance.  Clothing or other flammable material should not be placed on or near the appli-
ance.  Risk of electrical shock.  Switch the household breaker off or remove fuse before servicing unit.
Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct
discharge only without duct connection).
Minimum Clearances to Combustibles
To Adjacent Wall:
     From glass edge .......................................  7 3/4"
     From side of Rectangular fascia ..............  3"
     From side of Arched fascia ......................  3"
Back to enclosure (from stand-offs) .............  0"
Top to enclosure (from stand-offs) ...............  0"
Sides to enclosure (from stand-offs) .............  0"
Hearth Extension:
     Does not require hearth extension or
      non-combustible floor beneath appliance.
To Mantel:
     From top of glass edge ............................. 30 1/2"
     From top of Rectangular Facia ................  24"
     From top of Arched Facia ........................  22 5/8"
To maximum 1/2" top front facing:
     From top of glass edge ............................. 20 1/4"
     From Arched Facia .................................. 12 1/4"
     From Rectangular Facia .......................... 14"
Flue Vent .......................................................  1"
* See Owner’s Manual For Additional Mantel
Clearances and Options
STANDARDS/CLEARANCES LABEL
SAFETY 