Hearth & Home Technologies GARNET-D-MBK Manuale Utente

Pagina di 56
September 1, 2008
Page  25
Quadra-Fire · Garnet-T · 7016-127F
6
Gas Information
A.  Fuel Conversions
Before making gas connections ensure that the appliance 
being installed is compatible with the available gas type.
Any natural or propane gas conversions necessary to meet 
the appliance and locality needs must be made by a quali-
fied technician using Hearth & Home Technologies specified 
and approved parts.
1. Converting to LP Gas
Figure 6.1
   Lift off the appliance top and place it on a flat sur-
face, with the porcelain side up to prevent damage. Remove 
the appliance front by sliding it upwards in the grooves, being 
careful not to chip the porcelain. Lay the appliance front face 
up on a flat surface.  
Remove burner: First remove ONLY the two screws indi-
cated in. DO NOT remove the screws from the burner top. 
Lift the burner up and out of the firebox.
Figure 6.2
   Pull off pilot hood and set aside.  NOTE: Do not 
remove the wire clip.
Figure 6.3
   Use a 5/32 in. Allen wrench to remove the pilot 
injector.  
Replace pilot injector with the appropriate size injector supplied 
with the appliance (#35 for Propane, #62 for Natural Gas).  
Replace pilot hood, snapping into position. Be sure to align 
notch on left side of pilot hood.
Figure 6.4
   Remove main burner orifice using a 3/8 in. wrench.  
Replace orifice with the proper size as indicated below for 
your gas type and venting.
 
 
PROPANE 
    NATURAL GAS
 #56 
#49 
Reinstall burner. 
KIT CONTENTS:  Replacement orifice; replacement pilot 
injector; valve regulator; conversion label.
TOOLS REQUIRED:  Power drill (a 90° drill is helpful); 
Slotted screwdriver or Torx TH20; #2 Phillips bit; 5/32" 
Allen wrench; 3/8" open end
 wrench.
Remove 2 screws
MILLIVOT GENERATOR
PILOT HOOD
THERMOCOUPLE
5/32 in. Allen 
wrench
NOTE: Gas conversions should only be performed 
by a qualified service person, and/or where required 
by state and local codes, licensed installer/service 
technician. In the Commonwealth of Massachusetts, 
installation must be performed by a licensed plumber 
or gas fitter.