   7004-187F  September 1, 2008
Yosemite Wood Stove
LISTINGS and SAFETY NOTICES
WARNING !  DO NOT ATTEMPT TO OPERATE THIS WOODSTOVE 
WITHOUT READING AND UNDERSTANDING THESE OPERATING 
INSTRUCTIONS THOROUGHLY.  FAILURE TO OPERATE THIS 
APPLIANCE PROPERLY MAY CAUSE A HOUSE FIRE.
WARNING!  NEVER DRAW OUTSIDE COMBUSTION AIR FROM A 
WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED 
SPACE SUCH AS AN ATTIC OR GARAGE.
These installation instructions describe the installation and opera-
tion of the QUADRA-FIRE YOSEMITE woodstove.  This stove 
meets the U.S. Environmental Protection Agency’s 1990 particulate 
emission standards.  The Yosemite is listed by OMNI-Test Labora-
tories, Inc. to UL Safety Standard 1482, UL737 and ULC S627-00, 
and (UM) 84-HUD. The Yosemite is approved for mobile home 
installations when not installed in a sleeping room and when an 
outside combustion air inlet is provided.  The structural integrity of 
the mobile home floor, ceiling, and walls must be maintained.  Never 
use a single wall connector (stove pipe) only double-wall connector 
pipe.  The stove must be properly grounded to the frame of the 
mobile home.  Outside Air Kit, Part 831-1780 must be installed in 
a mobile home installation. 
Check with your local building code agency before you begin your 
installation to ensure compliance with local codes, including the 
need for permits and follow-up inspections.  Be sure local building 
codes do not supersede UL specifications and always obtain a 
building permit so that insurance protection benefits cannot be 
unexpectedly cancelled.  If any assistance is required during 
installation, please contact your local dealer.
Inspect and clean vent system frequently in accordance with the 
instructions contained in this manual.  Do not connect this unit to 
a chimney serving another appliance.
When using optional Blower, Part 831-1701, route power cord away 
from unit. Do not route cord under or in front of appliance.  
Do not elevate fire. Build wood fire directly on firebrick.  
Do not overfire - if heater or chimney connector glows, you are 
overfiring.  Stove thermometer recommended.
Operate only with the door closed.  Open only to add fuel to the fire 
unless using firescreen.   Operating with the door open can cause 
hot embers or sparks to fall out and a fire may result.
INSTALLATION MATERIALS NEEDED FOR YOUR SAFETY
CHIMNEY CONNECTOR (also known as flue pipe or stove pipe):  
The chimney connector joins the stove to the chimney (see 
page 11)
.  It must be 6 inch (152mm) minimum diameter 24 
MSG black or blued steel, or an approved air-insulated double 
wall venting pipe.
THIMBLE:  A manufactured or site-constructed device installed in 
combustible walls through which the chimney connector passes 
to the chimney (see pages 13-14).  It is intended to keep the 
walls from igniting.
CHIMNEY SYSTEMS:
A.  APPROVED MASONRY (see specifications on page 14) 
with at least 5/8” (16mm) fire clay lining joined with refractory 
cement or other listed system suitable for use with wood 
stoves.
B.  PREFABRICATED 6 inch (152mm) listed high temperature 
(UL 103 HT or ULC S629) chimney.  Components required 
by manufacturers for installation such as the chimney support 
base, firestop (as appropriate), attic insulation shield, insulated 
tee, etc., are necessary to assure a safe chimney installation.  
Use only components manufactured for the chimney.  Chimney 
installation should meet NFPA 211 standards.
FIRE SAFETY:  To provide reasonable fire safety, the following 
should be given serious consideration:
1.  Install at least one smoke detector on each floor of your 
home to ensure your safety.  They should be located away 
from the heating appliance and close to the sleeping areas.  
Follow the smoke detector manufacturer’s placement 
and installation instructions, and be sure to maintain 
regularly.  
2. 
A conveniently located Class A fire extinguisher to contend 
with small fires resulting from burning embers.
3. 
A practiced evacuation plan, consisting of at least 2  
escape routes.
4. 
A plan to deal with a chimney fire as follows:
 
In the event of a chimney fire:
A. 
Notify fire department.
B. 
Prepare occupants for immediate evacuation.
C. 
Close all openings into the stove.
D. 
While awaiting fire department, watch for ignition of 
adjacent combustibles from overheated stove pipe, 
hot embers or sparks from the chimney.
VENTING SYSTEM
The venting system consists of a chimney connector and a 
chimney.  These get extremely hot during use.  Temperatures 
inside the chimney may exceed 2000
°F (1100°C) in the event of 
a creosote fire.  To protect against the possibility of a house fire, 
the chimney connector and chimney must be properly installed 
and maintained.  An approved thimble must be used when a 
connection is made through a combustible wall to a chimney.  
A chimney support package must be used when a connection 
is made through the ceiling to a prefabricated chimney.  These 
accessories are absolutely necessary to provide safe clearances 
to combustible wall and ceiling material.  Follow venting 
manufacturer’s clearances when installing venting system.
This stove may be connected to a lined masonry chimney or a 
listed high temperature prefabricated approved metal chimney.  
Do not connect it to a chimney serving another appliance.  To do 
so will affect the safe operation of both appliances.
WARNING!  THIS APPLIANCE IS HOT WHILE IN OPERATION AND 
MAY REMAIN SO UP TO 40 MINUTES AFTER THERE IS NO FUEL 
IN THE FIREBOX.  IF THIS APPLIANCE IS IN A HIGH TRAFFIC 
AREA OR CHILDREN MAY BE NEAR IT IS RECOMMENDED THAT 
YOU PURCHASE A DECORATIVE BARRIOR TO GO IN FRONT OF 
THE APPLIANCE.  ALWAYS KEEP CHILDREN AWAY WHILE IT IS 
OPERATING AND DO NOT LET ANYONE OPERATE THIS APPLI-
ANCE UNLESS THEY ARE FAMILIAR WITH THESE OPERATION 
INSTRUCTIONS.