Hearth & Home Technologies CASTILE-GAS-CSB Manuale Utente

Pagina di 56
September 1, 2008
Page  7
Quadra-Fire · Castile Gas Stove · 7023-111E
3
Appliance Location and Clearances
A. Selecting Appliance Location
NOTE: 
·  
Illustrations reflect typical installations and are FOR 
 
DESIGN PURPOSES ONLY.
·
    Illustrations/diagrams are not drawn to scale.
·
   Actual installation may vary due to individual design   
 preference.
When selecting a location for your appliance it is important to 
consider the required clearances to walls (see Figure 3.1).  
Figure 3.1   
WARNING
Fire Risk
Provide adequate clearance:
•  Around air openings
• To 
combustibles
•  For service access
Locate appliance away from traffic areas.
Fire Risk.
  Locate and install appliance to all 
clearance specifications in manual.
WARNING
B. Clearances 
Model
A
B
C
D
E
F
Castile Gas Stove
Inches 
8-1/2
1/4
1
54
36
40
Millimeters
216
6
24
1372
914
1016
NOTE:  For actual appliance dimensions refer to 
Section 12.
NOTE: Flooring beneath appliance may reach 90 degrees 
plus room ambient temperature. Check with flooring 
manufacturer for maximum temperature allowed on flooring 
surfaces.
It is permissible to place the appliance on carpet.
CAUTION
Some carpet materials may be sensitive to radiant heat from the 
appliance causing discoloration or odor.
Fire Risk. 
Odor Risk.
Tipping Risk
•  Install appliance on a stable, level platform/
floor strong enough to support appliance 
without tipping. 
•  USE wood flooring, ceramic tile, brick hearth 
or high pressure laminate flooring applied 
directly over the sub-flooring material.
WARNING
D
A
A
E
A
F
A
C
C
B