tibles must be maintained from vehicles parked 
below the heater.
• When installed over hoists, the required safe dis-
tances from combustibles must be maintained from 
the uppermost point of the combustible materials 
placed on the hoist.
4.5.3 Hazardous Locations
Where there is the possibility of exposure to combus-
tible airborne material or vapor, consult the local Fire 
Marshal, the Fire Insurance Carrier or other authori-
ties for approval of the proposed installation.
4.6 Heater Location
It is the Installer’s Responsibility to choose a suitable 
mounting location for the heater. The Installer must 
follow the guidelines below as stated in the Installa-
tion Manual. Before using your heater, check the 
location. If the location does not follow these guide-
lines, do not use the heater. Immediately contact 
your installer.
• The heater must meet the minimum mounting 
height requirement of 7' (2.1 m) above the floor. For 
aircraft hangars and public garages, the heater must 
meet the minimum mounting height requirement of 
8' (2.4 m) above the floor.
• The proposed mounting location allows for the 
required safe distances from combustibles such as 
vehicles, wood, gasoline and flammable objects, liq-
uids and vapors.
• The proposed location of the heater will not restrict 
motion of passageway doors or windows.
• The proposed location will not interfere with opera-
tion of the overhead garage door, or allow the door 
to enter the required safe distances from combusti-
bles.
• The proposed location will provide the best cover-
age of the total area to be heated.
• Consideration be given to the types of vehicles that 
will be parked in the garage (cars, vans, boats, RV's, 
etc.).
• The proposed location will allow for the required safe 
distances from combustibles with respect to the 
vehicles parked in the garage.
• The proposed location will allow the required utilities 
(i.e.: gas and electric) and venting to be installed 
(maximum vent length is 10' [3 m]).
• Sufficient clearances will exist to allow for easy 
access to the service door.
• Overhead structural members (rafters, beams, etc.) 
are accessible for attaching the heater.