When facing the front of the appliance the following minimum
clearances to combustible construction must be maintained.
clearances to combustible construction must be maintained.
Left side 5 inches (127mm). Right side 5 inches (127mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Do not install in alcove or closet.
Rear wall 0 inches (0mm). Ceiling 36 inches (914mm).
Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).
Provide adequate clearances around air openings.
Adequate accessibility clearances for purposes of servicing and
proper operation must be provide
Adequate accessibility clearances for purposes of servicing and
proper operation must be provide
d.
Figure 3
Figure 4
COMBUSTIBLE MATERIAL
Do not attach combustible material to the mantel of your fireplace.
This is a fire hazard.
This is a fire hazard.
Figure 5
No greeting card, stocking or ornamentation of any type should be
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
placed on or attached to the fireplace. This is a heating appliance.
The flow of heat can ignite combustibles.
Figure 6
CLEARANCES