INSTALLING OPTIONAL BLOWER SRB-18T OR SRB-30T 
If heater is installed onto the wall, in order to install the optional blower, 
the heater must be removed from the wall.  If heater is installed on SRS-18 
or SRS-30 optional floor stand there is adequate access area available to 
install the optional blower.
  1.  Turn "OFF" gas supply to the heater.
  2.  Remove lower louver from casing assembly (2 screws).
  3.  Remove reflector from casing assembly (2 screws).
  4.  Remove upper louver from casing assembly (2 screws).
  5.  Insert the fan control wires and the upper portion of the fan control 
through the 3/4" (19mm) diameter hole on the bottom side of the 
top heat shield.  The fan control wires will enter into the top portion 
of the heater and the fan control disc will be facing the main burner. 
Attach fan control to the bottom side of the top heat shield with (2) 
screws provided with the optional blower.
  6.  Route  cord  set  through  9/16"  (14mm)  diameter  hole  on  casing 
assembly back.  Insert approximately 3" (76mm) of cord set into 
casing assembly back.
  7.  When you are facing the front of the heater, position the optional 
blower assembly onto the top heat shield of the heater.  The motor 
wire  harness  should  be  facing  into  the  top,  right  portion  of  the 
heater.
  8.  Attach (1) pin terminal from black (hot) wire, smooth insulation on 
cord set to (1) socket terminal on fan control wire harness.  
  9.  Attach (1) pin terminal from black (neutral) wire, ribbed insulation 
on cord set to (1) socket terminal from white (neutral) wire on motor 
wire harness.
  10.  Attach (1) pin terminal on fan control wire harness to (1) socket 
terminal from black (hot) wire on motor wire harness.
  11.  Attach the green ground wire from the motor wire harness and the 
green ground wire from the cord set to the bottom right side of the 
blower housing with (1) screw provided with the optional blower.
  12.  With the heater standing upright, position the air discharge opening 
of the blower housing downward.  Place the bottom flange of the 
blower housing over the top edge of the top heat  shield.  Insert the 
blower housing into the top portion of the heater by pivoting the 
blower housing upward 90°.  Attach the blower housing to the casing 
assembly with (4) screws provided with the optional blower.
  13.  Grasp cord set at casing assembly back and pull excess cord set 
through casing assembly back.  Secure cord set in casing assembly 
back with the strain relief provided with the optional blower.
  14.  Installation  of  optional  blower  SRB-18T  or  SRB-30T  is 
completed.
  15.  If heater was removed from the wall, in order to install SRB-18T or 
SRB-30T optional blower, check for gas leaks at all gas connections 
before lower louver is replaced onto casing assembly.
Attention!  After optional blower has been installed use the following steps 
to properly align the upper louver and the reflector with the heat shield.  
  A.  When replacing upper louver, be sure the bottom lip of upper louver 
goes behind the heat shield.
  B.  When replacing reflector, be sure the top lip of reflector goes in front 
of the heat shield.
Excessive Blower Wheel Noise
ATTENTION! If your blower assembly develops a squeal, hum or grinding 
noise, it indicates dirt or debris on shaft of blower wheel. Use the following 
steps to clean shaft of blower wheel.
  1.  Remove red rubber grommet with brass bushing or black rubber 
grommet with brass bushing from end of blower wheel shaft opposite 
motor.
  2.  Clean blower wheel shaft with cotton cloth.
  3.  Place  1  or  2  drops  of  all  purpose  oil  on  END  of  blower  wheel 
shaft.
  4.  Replace red rubber grommet with brass bushing or black rubber 
grommet with brass bushing onto end of blower wheel shaft. Attention: 
The red rubber grommet with brass bushing or the black rubber 
grommet with brass bushing must "snap-back" into position.
  5.  Cleaning of blower wheel shaft is completed.
SRB-18T and SRB-30T
 for Unvented Room Heaters  BF-10, BF-20 and BF-30
HEAT SHIELD
FAN CONTROL
BRACKET
(BF-10 ONL
Y)
FAN CONTROL
GROUND W
IRE SCREW
CORD
SET HOLE
IN
CASING
BACK
REFLEC
TOR AND
LOUVER
S ARE
REMOVED
FROM CASING
ASSEMBL
Y
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS