OPTIONAL SINGLE SPEED BLOWER INSTALLATION INSTRUCTIONS
Attention:  Install blower assembly before connecting gas inlet 
supply line.
Wiring
The appliance, when installed, must be electrically grounded in 
accordance  with  local  codes  or,  in  the  absence  of  local  codes, 
with  the  National  Electrical  Code, ANSI/NFPA  70,  if  an  exter-
nal electrical source is utilized. This appliance is equipped with 
a  three-prong  [grounding]  plug  for  your  protection  against 
shock hazard and should be plugged directly into a properly 
grounded three-prong receptacle. Do not cut or remove the 
grounding prong from this plug. For an ungrounded receptacle, 
an adapter, which has two prongs and a wire for grounding, can 
be purchased, plugged into the ungrounded receptacle and its wire 
connected to the receptacle mounting screw. With this wire com-
pleting the ground, the appliance cord plug can be plugged into 
the adapter and be electrically grounded.
Caution: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous 
operation. Verify proper operation after servicing.
Note: Junction box on right side of firebox must be pre-wired at 
time of firebox installation for use with blower assembly. A 
standard wall ON/OFF wall switch or optional SCV1 Vari-
able Speed Control Kit should be installed to activate pow-
er to the Firebox, and control the operation of the FBB5 
Blower assembly. It is recommended that installation of the 
wiring be performed by a qualified electrician. See Figure 
25.
1.  If installed, turn OFF gas supply to firebox/gas log.
2.  If applicable, turn OFF electric supply to firebox.
  CAUTION:  ALL  WIRING  SHOULD  BE  DONE  BY 
A  QUALIFIED  ELECTRICIAN  AND  SHALL  BE  IN 
COMPLIANCE  WITH ALL  LOCAL,  CITY AND  STATE 
BUILDING CODES. BEFORE MAKING THE ELECTRI-
CAL CONNECTION, MAKE SURE THAT MAIN POWER 
SUPPLY IS DISCONNECTED. THE APPLIANCE, WHEN 
INSTALLED,  MUST  BE  ELECTRICALLY  GROUNDED 
IN ACCORDANCE  WITH  LOCAL  CODES,  WITH  THE 
NATIONAL  ELECTRICAL  CODE ANSI/NFPA  70  (LAT-
EST EDITION).
A factory installed junction box is located on the lower right 
side of the firebox. Wiring must be fed to the junction box 
and  attached  to  the  receptacle  that  is  provided.  From  right 
side of the firebox, remove the screw securing the junction 
box assembly. Leave approximately 6” of wire in the junction 
box for connection.
Attach black wire to one side of the receptacle and white wire 
to opposite side of receptacle. The ground wire should be at-
tached to the green (ground) screw.
Install  the  recepticle  into  the  junction  box.  Attach  cover 
plate.
Attention: If installed, do not damage gas inlet supply line 
when blower assembly is inserted into firebox. In some cases, 
removal the gas inlet supply line may be necessary. 
3.  Determine which type of firebox you have prior to installa-
tion. See Figures 26 and 27.
Figure 25
REMOVE BOTTOM LOUVER TO
INSTALL BLOWER ASSEMBLY
Figure 26
REMOVE COVER PLATE TO
INSTALL BLOWER ASSEMBLY
Figure 27
Deluxe Louvered 
Models
Deluxe Flush Face 
Models