The firebox is designed to accept a 3/8-inch gas line for an approved 
vent-free gas logset. Have the line installed by a qualified service 
person in accordance with all building codes. Consult local building 
codes to properly size the gas supply line leading to the 3/8-inch 
hook-up at the unit. The state of Massachusetts requires that a 
flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. 
See 
Figure 11. On  models with ceramic brick panels installed, carefully 
remove the indented knockout in the ceramic brick panel using a 
drill or utility knife. See Figure 12. 
When installing optional ceramic fiber side panels into firebox, 
lay panel on a flat surface. Remove the gas line knockout (round 
depression) in the appropriate side panel using a drill or utility 
knife.
After the brick panel knockout is removed, the firebox wrap may 
have a round metal knockout that must be removed also. Use a 
screwdriver to punch out the metal knockout.
Check gas type. Use only the gas type indicated on the gas log 
set rating plate. If the gas listed on the plate is not your type of 
gas supply, DO NOT INSTALL. Contact your dealer for proper 
model.
Always use an external regulator for all LP fireboxes to reduce the 
supply tank pressure to a maximum of 14" w.c. This is in addition 
to the regulator fitted to the log set.
WARNING:  CONNECTION  DIRECTLY  TO  AN 
UNREGULATED L.P. TANK CAN CAUSE EXPLOSION. 
Install only a ANSI Z21.11.2 vent-free log set into this firebox. 
Figure 11
Extended Hoods
If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that 
will extend out 2" farther out into the room. Contact your local dealer for details.
Finishing
All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-
combustible material. 
Hearth extensions are recommended, but not required for these  fireboxes.
VB4H32BL
Standard Black
VB4H36BL
Standard Black
VB4H42BL
Standard Black
VB4H32BR
Polished Brass
VB4H36BR
Polished Brass
VB4H42BR
Polished Brass
VB4H32SS
Stainless Steel
VB4H36SS
Stainless Steel
VB4H42SS
Stainless Steel
VB4H32HP
Hammered Pewter
VB4H36HP
Hammered Pewter
VB4H42HP
Hammered Pewter
GAS ACCESS HOLES
Figure 12
INSTALLING HOOD (continued)
GAS LINE CONNECTION