- Install the wall switch in a convenient location. Route a proper sized wire from 
the switch or the thermostat to the gas valve. 
 
  Distance 
between 
valve 
  Wire 
gage 
  and 
switch 
 
 
 
 
8’ 
 
 
 
 
 
22 
 
 
 
12’ 
 
 
 
 
 
20 
 
 
 
20’ 
 
 
 
 
 
18 
 
 
 
32’ 
 
 
 
 
 
16 
 
 
 
50’ 
 
 
 
 
 
14 
 
 
- Connect the wires in serial with the face plate flame switch ( green wires ). 
 
 
NOTE : DO NOT CONNECT THE WALL SWITCH WIRE OR THE VALVE TO 
120 VOLTS POWER SUPPLY LINE. THE VALVE IS OPERATED BY ITS OWN 
MILLIVOLT SYSTEM. 
   
 
 
 
 
19. 
If you want to turn the main burner ON and OFF using a wireless remote control, 
install the remote control module apart from the gas valve and as close to the front 
as possible.  Connect the wires as shown. 
 