Hampton Direct H35-LP1 Manuale Utente

Pagina di 48
Hampton
®
 H35 Direct Vent Freestanding Gas Stove
13
INSTALLATION
Offset to Vertical Terminations
VENTING ARRANGEMENTS
Vertical Terminations Systems for 
Residential Manufactured and Mobile Homes
The shaded area in the diagram below shows all allowable combinations of straight vertical 
and offset to vertical runs with vertical terminations.
 Maximum two 45
o
 elbows.
If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" clearance to combus-
tibles.
May be installed in Manufactured (Mobile) Homes after fi rst sale.
Horizontal Terminations for All 
Venting Systems
The shaded areas in the diagram below show 
all allowable combinations of vertical runs 
with horizontal terminations.  Maximum one 
90
O
 elbow (two  45
elbows equal one 90
o
 
elbow).
Propane and Natural Gas: 
Residential, Manufactured and 
Mobile Homes Installations
The venting arrangements diagrammed below, 
have a min. of 75% (fl ue loss) effi ciency with Fan 
Off, as required for manufactured homes. (Actual 
effi ciency may be as high as 85%)
May be installed in Manufactured (Mobile) 
Homes after fi rst sale.
ROTATING 45
O
 ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS
1) Remove all 4 screws that secure 
the elbow to the unit using a 1/4" 
magnetic nut driver.
2) Rotate the elbow 180
3) Secure the elbow by securing 
it with the 4 screws. 
Remove all 4 screws 
and washers
NOTE: See "Vent Restrictor Position" section for 
installation instructions for the Vent Restrictor 
Position.