Hampton Direct H35-LP1 Manuale Utente

Pagina di 48
Hampton
®
 H35 Direct Vent Freestanding Gas Stove
21
Diagram 2a
Diagram 3
 
Below Grade Snorkel Installation
 
If the Snorkel Termination must be installed 
below grade, i.e. basement application, 
proper drainage must be provided to prevent 
water from entering the Snorkel Termination. 
Refer to Dura-Vent Installation instructions 
for details. Do not attempt to enclose the 
Snorkel within the wall, or any other type 
of enclosure.
3)  With the pipe attached to the stove, slide 
the stove into its correct location, and mark 
the wall for a 10" x 10" (inside dimensions) 
square hole. The center of the square 
hole should line up with the centerline of 
the horizontal pipe, as shown in diagram 
3. Cut and frame the 10 inch square hole 
in the exterior wall where the vent will be 
terminated. If the wall being penetrated is 
constructed of non-combustible material, i.e. 
masonry block or concrete, a 7" diameter 
hole is acceptable.
*As specifi ed in CGA 
B149 Installation Code. 
Local codes or regula-
tions may require differ-
ent clearances.
Diagram 2
INSTALLATION
Diagram 1: 
Hint: Apply 
silicone to 
female end.
DURA-VENT 
HORIZONTAL 
INSTALLATIONS
1)  Set the unit in its desired location. Check 
to determine if wall studs or roof rafters 
are in the way when the venting system is 
attached. If this is the case, you may want 
to adjust the location of the unit.
2)  Direct Vent pipe and fi ttings are designed 
with special twist-lock connections to con-
nect the venting system to the appliance 
fl ue outlet. A twist-lock appliance adapter is 
installed on the unit at the factory. Assemble 
the desired combination of pipe and elbows 
to the appliance adapter with pipe seams 
oriented towards the wall or ceiling, as much 
out of view as possible. The fi nal position-
ing of the pipe and 90
o
 elbow assembly is 
determined by the mounting orientation of 
the adapter on the stove and twist-locked 
for a solid connection.
 b)  Horizontal runs of vent must be sup-
ported every three feet. Wall straps are 
available for this purpose.
 c)  Snorkel Terminations:
 
 
For installations requiring a vertical rise 
on the exterior of the building, 14-inch 
and 36-inch tall Snorkel Terminations 
and the Riser Vent  as shown in Diagrams 
2 & 2a are available. Follow the same 
installation procedures as used for stand-
ard Horizontal Termination. NEVER 
install the snorkel upside down.
 
Note:
 a)  Twist-lock procedure: Four indentations, 
located on the female ends of pipes and 
fi ttings, are designed to slide straight 
onto the male ends of adjacent pipes 
and fi ttings, by orienting the four pipe 
indentations so they match and slide in 
to the four entry slots on the male ends 
(Diagram 1). Push the pipe sections 
completely  together, then twist-lock 
one section clockwise approximately 
one-quarter turn, until the two sections 
are fully locked. The female locking lugs 
will not be visible from the outside on 
the Black Pipe or fi ttings. They may be 
located by examining the inside of the 
female ends. Apply sealant "Mill-Pac" to 
inner pipe and high temp silicone sealant 
to outer pipe on every twist-lock joint.