Hampton Direct H35-LP1 Manuale Utente

Pagina di 48
Hampton
®
 H35 Direct Vent Freestanding Gas Stove
7
INSTALLATION
manufactured home the unit must be bolted 
down to the fl oor. 
4)  This appliance is Listed for bedroom  instal-
lations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
5)  This appliance is Listed for Alcove installa-
tions, maintain minimum Alcove clearances 
as follows,   minimum width of 40" (1016mm), 
a maximum depth of 36" (914mm), and 
minimum ceiling height of 64" (1626mm) 
from fl oor to ceiling.
6)  We recommend that you plan your instal-
lation on paper using exact measurements 
for clearances and fl oor protection before 
actually installing this appliance.  Have a 
qualifi ed building inspector review your plans 
before installation.
GENERAL SAFETY 
INFORMATION
1) The 
appliance 
installation 
must 
conform 
with 
local Canadian Electrical Code.
2)  The appliance when installed, must be 
electrically grounded in accordance with 
local codes, or in the absence of local codes 
with the current National Electrical Code, 
ANSI/NFPA 70 or CSA C22.1 Canadian 
Electrical Code.
3)  The  appliance should be inspected for 
shipping damage before use and serv-
iced annually by a professional service 
person
. More frequent cleaning may be 
required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative 
that control compartments, and circulating 
air passageways of the appliance be kept 
clean and free from excessive lint from 
carpeting.
4)  See general construction and assembly 
instructions. The appliance and vent should 
be enclosed when installed in or passing 
through a living area, where children may 
come in contact with it.  
5)  This appliance must be connected to the 
specifi ed vent and termination cap to the 
outside of the building envelope. 
Never 
vent to another room or inside a building.  
Make sure that the vent is fi tted as per the 
instructions starting in the "Exterior Vent 
Terminal Locations" section.
6)  Inspect the venting system annually for 
blockage and any signs of deterioration.   
7)  Venting terminals shall not be recessed into 
a wall or siding.
8)  Any safety glass removed for servicing 
must be replaced prior to operating the ap-
pliance.  
9)  To prevent injury, do not allow anyone who 
is  unfamiliar with the operation to use the 
fi replace.  
INSTALLATION 
CHECKLIST
1)  Locate your appliance. Refer to the following 
sections: 
 
a. Clearances to combustibles
 
b. Locating Your Gas Stove
 
c. For venting requirements, see "Venting 
    Introduction" to "Venting Arrangements"   
          sections.
2)  Install Optional Fan. Refer to the "Optional 
Fan Installation" section. 
3)   Set vent restrictors. Refer to the "Vent Re-
strictor Position" section. 
4)  Install venting. Refer to the following sections 
where applicable: 
 
a. Check all venting requirements.    
    See "Venting Introduction" to "Venting 
 
     Arrangements" sections.
 
b. Vertical Termination with Co-linear Flex 
 
     System
 
c. DV Stove Horizontal Vent Kit
 d. 
Dura-Vent 
Termination 
Kit. 
5)  Make gas connections. Refer to the "Gas 
Connection" section
 
Test the pilot. Must be as per diagram in the 
"Maintenance Instruction" section.
 
If converting to Propane, make changes 
prior see the "Conversion from Natrual Gas 
to Propane" section.
6)  Test Gas Pressure. Refer to the "Gas Pipe 
Pressure Testing" section.
7)  Install standard and optional features.  Refer 
to the following sections where applicable: 
 
a. Log Set Installation
 b. 
Double 
Door 
Installation
 c. 
Decorative 
Door 
Grill 
Installation
 
d. Tile Inset Installation
 e. 
Wall 
Thermostat
 f. 
 
Remote 
Control
8)  Final check. Refer to the "Final Check" sec-
tion.
     Before leaving this unit with the customer, 
the installer must ensure that the appli-
ance is fi ring correctly and operation fully 
explained to customer
.
This includes:
1)  Clocking the appliance to ensure the correct 
fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.
2)  If required, adjusting the primary air to ensure 
that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that 
causes sooting or carboning that results 
in damage is not the responsibility of the 
manufacturer.
CLEARANCES TO 
COMBUSTIBLES
The clearances listed are MINIMUM distances. 
Measure the clearance to both the appliance 
and the chimney connector. The farthest 
distance is correct if the two clearances do 
not coincide.
 
For example, if the appliance is set as indicated 
in one of the fi gures but the connector is too 
close, move the stove until the correct clearance 
to the connector is obtained.  
This appliance may be installed only with the 
clearances as shown in the situations pictured. 
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances.
Emissions from burning  wood or gas could 
contain chemicals known to the State of Cali-
fornia to  cause cancer, birth defects or other 
reproductive harm.