CLEARANCES
Minimum clearances to combustibles for the fireplace are as follows:
Back, and sides
Back, and sides
0"/mm
Perpendicular walls
6" (152mm)
Floor
0"/mm
Ceiling to louver opening
42" (1067mm)
Front
36" (914mm)
Top of Standoffs
0"/mm
Vent
(See venting instructions for
specific venting clearances.)
specific venting clearances.)
Combustible material with a maximum thickness of 5/8" may be
flush with the top front of fireplace .
flush with the top front of fireplace .
FRAMING AND FINISHING
Figure 4 shows typical framing of this fireplace. Figure 5 shows
framing for corner installation. All minimum clearances must be met.
framing for corner installation. All minimum clearances must be met.
For available accessories for this fireplace, see Accessories on page
39. If you are using a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can install noncombus-
tible mantels at any height above the fireplace.
39. If you are using a separate combustible mantel piece, refer to
Figure 6 for proper installation height. You can install noncombus-
tible mantels at any height above the fireplace.
Note:
Noncombustible mantels may discolor!
PRE-INSTALLATION
PREPARATION
PREPARATION
Continued
NOTICE: This fireplace is intended for use as supple-
mental heat. Use this fireplace along with your pri-
mary heating system. Do not install this fireplace as
your primary heat source. If you have a central heat-
ing system, you may run system’s circulating blower
while using fireplace. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this fireplace as a heat source.
mental heat. Use this fireplace along with your pri-
mary heating system. Do not install this fireplace as
your primary heat source. If you have a central heat-
ing system, you may run system’s circulating blower
while using fireplace. This will help circulate the heat
throughout the house. In the event of a power outage,
you can use this fireplace as a heat source.
Figure 4 - Framing Clearances for Installation Against an Exterior
Wall
Wall
C
B
A
D
E
F
G
Top of Louver Opening
3
2
1
4
5
6
7
Wall
Figure 5 - Framing Clearances for Corner Installation
Ref. Mantel Depth Ref.
Mantel from Top
of Louver Opening
1
14" (356mm) A
16" (406mm)
2
12" (305mm) B
14" (356mm)
3
10" (254mm) C
12" (305mm)
4
8" (203mm)
D
10" (254mm)
5
6" (152mm)
E
8" (203mm)
6
4" (101mm)
F
6" (152mm)
7
2" (51mm)
G
4" (101mm)
Figure 6 - Clearances for Combustible Mantels
PRE-INSTALLATION PREPARATION
Clearances
Framing and Finishing
36
1
/
8
"
41
1
/
4
"
23
1
/
2
"
41"
41
1
/
4
"
35
3
/
4
"
15"
49
5
/
8
"
13
3
/
4
"
68
1
/
2
"
10
3
/
8
"