SAFETY INSTRUCTIONS                  
TO AVOID SERIOUS OR FATAL PERSONAL INJURY 
OR MAJOR PROPERTY DAMAGE, READ AND 
FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL 
AND ON PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE 
INSTALLATION AND OPERATION OF THIS UNIT 
AND MUST BE KEPT WITH THE PUMP.
This is a SAFETY ALERT SYMBOL.  
When you see this symbol on the pump 
or in the manual, look for one of the fol-
lowing signal words and be alert to the 
potential for personal injury or property 
damage.
Warns of hazards that WILL cause 
serious personal injury, death or major 
property damage.
Warns of hazards that CAN cause 
serious personal injury, death or major 
property damage.
Warns of hazards that CAN cause per-
sonal injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS  
 
 WHICH ARE VERY IMPORTANT AND  
 
 MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS 
AND WARNINGS PRIOR TO PERFORMING ANY 
WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
UNIT NOT DESIGNED FOR USE 
WITH HAZARDOUS LIQUIDS 
OR FLAMMABLE GASES. THESE 
FLUIDS MAY BE PRESENT IN 
CONTAINMENT AREAS.
   
NOTICE: INSPECT UNIT FOR DAMAGE AND  
 
REPORT ALL DAMAGE TO THE CARRIER  
 
OR DEALER IMMEDIATELY.
1.  Important Instructions
1. Inspect unit for damage. Report damage to carrier  
immediately.
2. Electrical supply must be a separate branch circuit 
with fuses or circuit breakers, wire sizes, etc., per 
National and Local electrical codes. Install an all-leg 
disconnect switch near pump. 
ALWAYS DISCONNECT  
 
ELECTRICAL POWER WHEN   
HANDLING PUMP OR CONTROLS.
DANGER
WARNING
CAUTION
WARNING
Hazardous fluids
can cause fire,
burns or death.
3. Motors must be wired for proper voltage (check 
nameplate). Wire size must limit maximum voltage 
drop to 0% of nameplate voltage at motor terminals, 
or motor life and pump performance will be lowered.
4. Single-Phase: Thermal protection for single-phase units 
is sometimes built-in (Check nameplate). If no built-in 
protection is provided, use a contactor with proper 
overload. Fusing is permissible if properly fused.
5. Three-Phase: Provide three-leg protection with proper 
size magnetic starter and thermal overloads.
6. Maximum Liquid Temperatures:
  ºF (00ºC) with standard seal.
  50ºF (0ºC) with optional high-temperature seal.
7. Maximum allowable operating pressure: 30 PSI  
(5 bars).
8. Maximum number of starts per hour: 0, evenly  
distributed.
9. Regular Inspection and Maintenance will increase  
 service life. Base schedule on operating time.
2. Installation
1.  Close-coupled units may be installed inclined or vertical. 
DO NOT INSTALL WITH MOTOR 
BELOW PUMP. CONDENSATION  
WILL BUILD UP IN MOTOR.
2. Locate pump as near liquid source as possible (below  
level of liquid for automatic operation).
3. Protect from freezing or floods.
4. Allow adequate space for servicing and ventilation.
5. For close-coupled pumps, the foundation must be flat  
and substantial to eliminate strain when tightening  
bolts. Use rubber mounts to minimize noise and  
vibration. Tighten motor hold-down bolts before  
connecting piping to pump.
6. For frame-mounted pumps, permanent and solid  
foundation is required for smooth operation. Bedplate  
must be grouted to a foundation with solid footing.
7. Place unit in position on wedges located at four points  
(Two below approximate center of driver and two  
below approximate center of pump). Adjust wedges to  
level unit, bringing coupling halves into reasonable  
alignment. Level or plumb suction and discharge  
flanges.
8. Make sure bedplate is not distorted and final coupling  
alignment can be made within the limits of movement  
of motor and by shimming if necessary.
9. Tighten foundation bolts finger tight and build dam  
around foundation. Pour grout under bedplate making  
sure the areas under pump and motor feet are filled  
solid. Allow grout to harden 48 hours before further  
tightening foundation bolts.
10. All piping must be supported independently of the 
pump, and must “line-up” naturally. Never draw 
piping into place by forcing the pump suction and 
discharge connections!
11. Angular alignment of the flanges can best be accom-
plished using calipers at bolt locations (See illustra-
tion).
WARNING
Hazardous voltage
can shock, burn or
cause death.
CAUTION