OPERATION
Continued
To Stop Heater
1. Unplug power cord from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater, page 7.
STORING,
TRANSPORTING,
OR SHIPPING
Note:
 
If shipping, transport companies require fuel tanks to be empty.
1. Drain fuel tank.
Note:
 
Some models have drain plug on underside of fuel tank. If so, remove
drain plug to drain all fuel. If heater does not have drain plug, drain fuel
through fuel cap opening. Be sure all fuel is removed.
2. Replace drain plug if provided.
3. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank,
stir, and drain again. This will prevent excess debris from clogging filters
during future use.
4. Replace fuel cap or drain plug. Properly dispose of old and dirty fuel. Check
with local automotive service stations that recycle oil.
5. If storing, store heater in dry place. Make sure storage place is free of dust and
corrosive fumes.
IMPORTANT:
 Do not store kerosene over summer months for use during next
heating season. Using old fuel could damage heater.
PREVENTATIVE
MAINTENANCE
SCHEDULE
Item
How Often
How To
Fuel tank
Flush every 150-200 hours
See Storing, Transporting, or
  of operation or as needed.
  Shipping, above.
Air output and
Replace every 500 hours of
See Air Output, Air Intake,
lint filters
  operation or once a year.
   and Lint Filters, page 14.
Air intake
Wash and dry with soap and
See Air Output, Air Intake,
filter
  water every 500 hours of
  and Lint Filters, page 14.
  operation or as needed.
Fuel filter
Clean twice a heating season
See Fuel Filter, page 11.
   or as needed.
Spark plug
Clean and regap every 600
See Spark Plug, pages 12 and 13.
   hours operation or replace
   as needed.
Fan blades
Clean every season or as needed. See Fan, page 18.
Motor
Not required/permanently
lubricated
 WARNING
Never service heater while it is plugged in, operating, or
hot. Severe burns and electrical shock can occur.