Front Panel 
Chassis
Accessory 
Wall Sleeve 
Accessory 
Outdoor Grille
Wall Sleeve 
Adapter
PTAC - Heat Pump and Electric Heat models_Prod Specs
Rearward Slope 
Outside Wall 
1/4" Slope
Inside Wall 
Specifications  
subject to change.
Product Dimensions
Height
Width
Depth
Max. Wall Thickness
Manufacturer 
Wall Sleeve Part Number
General Electric
Amana
Trane
Friedrich
16"
42"
13-13/16"
13-13/16"
Metal Sleeve RAB71
Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep 
Wall Sleeve 
Standard-Depth Wall Sleeve 
16 X 42 X 13-3/4-in. PXWS
Wall Cutout Dimensions
Height 
Width
16-5/16"
42-3/16"
PTAC Specifications
 Product Shipping Weight (approx.) – 141 Lbs.
 An electrical supply with grounded three-prong receptacle is required. 
The power supply circuit must be installed in accordance with current 
edition of National Electrical Code (ANSI/NFPA 70)  
and local codes & ordinances.  
 Voltage Rating – 230V / 208V / 60 Hz / 30 Amps
 Amps @ 230/208V Volts =  
(Cool) 6.7 / 7.5 Amps / (Electric Heater) 21.5 / 20.5 Amps
 Always consult local and national electric codes.
 Recommended Circuit Breaker – 30 Amps
 Unit equipped with 230/208V 3-wire power supply cord, NEMA plug 
type 6-30P, approximately 66" long.
 In order for condensate water to drain properly inside the unit, the 
sleeve must be installed properly: Level from right to left with a slight 
1/4" rearward pitch from the indoor side to the outdoor side as shown in 
the illustration above. Refer to the Installation Instructions on the web. 
 The drain kit listed on the Frigidaire® PTAC Accessories page can 
be used for an internal or external drain. This applies to new and 
replacement installation.
New Installation
 For new installation, Frigidaire® PTAC Sleeves are available and 
recommended for proper installation. See accessories pages for  
sleeve options.*
 Standard PTAC installation requires 13-13/16" maximum wall thickness, 
unless a wall sleeve is used.
 If the PTAC unit protrudes more than 4", then it is suggested that it be 
installed with a subbase. See accessories pages for subbase options. 
Replacement Installation
 When replacing existing PTAC with new unit, refer to Product 
Installation Guide on web to identify existing wall-sleeve manufacturer 
and size compatibility. If proper installation and slope are suspect, 
then correct installation of Frigidaire® PTAC Sleeve options 
recommended. 
 For any sleeve retrofit application, be sure that the foam seals 
(factory-installed on the tube sheets) provide a good seal between 
the grille and the outdoor coil tube sheets. These foam seals provide 
a barrier that stops air from the inside mixing with air on the outside 
(known as air recirculation).
 Using Frigidaire® wall sleeve with Non-Frigidaire grille requires 
installation of an Accessory Baffle Kit, which ensures a good seal 
between the unit and exterior grille to prevent air recirculation. Air 
recirculation is a large contributor to performance loss and premature 
damage to major components. 
Note:  For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.
*See Frigidaire® PTAC accessories pages attached for optional accessories. 
Plug Type (NEMA)
6-30P
USA
 • 
10200 David Taylor Drive
 • 
Charlotte, NC 28262
 • 
1-866-942-1567
 • 
frigidaire.com 
CANADA
 • 
5855 Terry Fox Way
 • 
Mississauga, ON L5V 3E4
 • 
1-866-942-1567
 • 
frigidaire.ca
FRP15ETT2R 08/11 