Setup 
12
3A0096B
Setup
Tighten Clamps
. 4. Before starting, torque the screws (3) secur-
ing the four clamps (4) to 21-25 ft-lb (28-34 N•m).
Wet Cup
. 5. Before starting, fill the wet cup (P) 1/3 full 
with Graco Throat Seal Liquid (TSL) or compatible sol-
vent. 
NOTE: The wet cup has a covered fill port fitting. A plug 
(9) is shipped loose with the pump and can be installed 
in place of the covered fitting if desired.
Wet Cup Drain Fitting
As supplied, the side port of the wet cup is plugged. To 
install a drain tube, remove the plug and install the sup-
plied 90° tube fitting (R) in its place. Attach a 1/2 in. (13 
mm) ID flexible plastic tube (not supplied) to the fitting to 
drain any overflow to a pail.
Torque Wet Cup
MaxLife pumps use a special u-cup throat seal that is 
non-adjustable and does not require periodic torquing.
F
IG
. 4. Wet Cup
3
ti14668a
1
Torque to 21-25 ft-lb (28-34 N•m).
1
F
IG
. 5. Wet Cup
P
ti14667a
9
R