Lopi 028-S-75-2 Manuale Utente

Pagina di 40
10
Stove Installation 
(for qualified installers only)
© Travis Industries
100-01177
4060802
Bypass Handle Installation
The bypass handle is shipped inside the owner’s pack (along with a 1/8” hex wrench). With the set
screws loosened, line up the bypass handle with the bypass rod (Figure 4).  Press back on the bypass
lever and slide the handle into place.  NOTE: Several washers may be included on the bypass rod to
act as spacers –    
do not remove these washers
   .  Once in place, secure the handle by tightening
the two set screws.  Make sure the set screws are properly located over the holes in the bypass rod.
When tightened, the set screws will submerge below the surface of the handle (Figure 4).
Figure 4
Rear Vent Configuration
The rear vent configuration is only for masonry fireplace installations (hearth stove).  All steel chimney
applications require the top vent configuration.
The vent (chimney connector) may be directed to the rear of the appliance when installed into a masonry
fireplace.  See Figure 5 for details.
The flue collar is held in place with three bolts 
and two nuts.  Use two 7/16" open-end 
wrenches to remove the bolts and nuts.  
7/16" Wrench
NOTE: Make sure the gasket 
underneath the flue collar is properly 
located and seals the flue collar when 
it is installed.
Open the bypass - this 
allows for access to the 
nut under the flue collar.
Remove the flue collar and rotate it to the rear.  
Use the exiting bolts and nuts to attach the 
sides of the flue.  For the center connection 
use the bolt and acorn nut included in the 
owner's pack. 
Figure 5