Stove Installation 
(for qualified installers only)
© Travis Industries
100-01177
4060802
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation
requires a UBC approved
masonry connector or
other method approved by
the NFPA 211 standard.
See Chimney Connector
Requirements on page 11
for further details.
Make sure the 
clean-out seals in 
place.
Clay Liner
See the section "Stove 
Placement Requirements" for 
minimum clearances required.
Min. 18" 
clearance 
to ceiling
This type of 
installation requires 
a UBC approved 
masonry connector 
or other method 
approved by the 
NFPA 211 standard.
Chimney connector sections
NOTE: The chimney must have a 
clay tile liner.  If it does not, the 
installation must use a positive 
connection (full reline).  The 
entire fireplace and chimney must 
be clean, undamaged, and meet 
all local building codes (UBC, 
etc.).  Damage must be repaired 
prior to installation.  The chimney 
must be 15' to 33' tall.
See the section 
"Floor Protection 
Requirements" 
Full Re-Line 
(recommended)
Figure 17