Operating Your Appliance
21
© Travis Industries
100-01177
4060802
Bypass Operation
The bypass controls the flow of smoke inside the heater.  When open, smoke goes directly up the flue,
creating more draft.  When closed, the smoke goes through the combustor, utilizing the secondary
combustion system and making the heater more efficient.
 
When starting or re-loading the stove, open the bypass.
 
Once the stove reaches full temperature – typically 45 minutes, close the bypass.
To close the bypass, simply  rotate the 
handle down.
To open the bypass, push on the 
lever and rotate the handle up.
Bypass CLOSED
Used for normal 
operation
Bypass OPEN
Used for starting 
and re-loading
AAAAA
AAAAA
AAAAA
AAAAA
AAAA
AAAA
AAAA
AA
AA
AA
AA
If the bypass does not latch in the closed position, you will need to adjust the bypass latch (see page 33).
Loading Lid Operation
Open the lid 1" for a few 
seconds to allow air to 
enter the firebox.
Open the bypass first (this 
helps prevent smoke from 
entering the room).
Lift the lid upward.
A log poker is 
provided with this 
stove.  It attaches 
with a clip to to the 
back of the stove.
WARNING: This part 
becomes hot - use gloves.
a
b
Open the air control and allow air to flow 
into the firebox for 30 seconds.
c
d
Do not wear loose clothing while re-loading the stove.  Any item dangling above the opening may ignite.
Carefully close the loading lid after use.  Allowing it to “slam” shut may damage the stove.