Chimney Requirements
 
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
 
UL 103 HT Chimney must be used from the first ceiling or floor penetration to the chimney cap.
 
Use 6" diameter type UL 103 HT chimney from one manufacturer (do not mix brands) or code
approved masonry chimney with a flue liner.
 
Chimney must be fastened to each adjoining section.
 
Follow the chimney manufacturer's clearances and requirements.
 
Use the chimney manufacturer's fire stops, attic guards, roof supports, and flashings when passing
through a ceiling
 
No more than 180
o
 of elbows (two 90
o
 elbows, or two 45
o
 & one 90
o
 elbow, etc.) may be used for the
entire system (connector and chimney).
NOTE:  Additional elbows may be allowed if draft is sufficient.  Whenever elbows are used the draft is
adversely affected.  Additional chimney height may be required to boost draft.
A
A
A
AA
AA
A
A
A
A
A
AA
AA
A
A
A
A
A
Chimney Cap
(See the section "Chimney Termination 
Requirements" for more details)
A
AA
AA
AA
AA
AA
AA
AA
Factory Built Chimney Sections
Minimum Air Space to Combustibles 
(See Chimney Manufacturer's 
Instructions - usually 2")
Floor Penetration Equipment 
(Attic Radiation Shield with Chimney Support)
Reduced Clearance Chimney 
Connector Sections
Roof Penetration Equipment (Roof 
Radiation Shield, Flashing, Storm Collar)
}
}
A
A
A
Stove Clearance 
(as outlined in this manual)
A
A
A
A
AA
AA
A
A
A
A
A
AA
AA
A
A
A
A
A
}
Standard residential installations with reduced 
clearance connector may use the clearance determined by 
the manufacturer of the connector for the connector to wall 
clearance or the clearance listed in this manual.
Mobile home installations must use the the reduced 
clearance connector clearances listed in this manual under 
“Additional Requirements for Mobile Home Installations”.
Minimum System 15' 
Maximum System 33'
AAAAA
AAAAA
Floor 
Protection
Figure 5
Drafting
Performance
This appliance relies upon natural draft to operate.  External forces, such as wind,
barometric pressure, topography, or factors of the home (negative pressure from exhaust
fans, chimneys, air infiltration, etc.), may adversely affect draft.  Travis Industries can not be
responsible for external forces leading to less than optimal performance.