Lopi 1750 Manuale Utente

Pagina di 36
14
Stove Installation 
(for qualified installers only)
© Travis Industries
100-01179
4060926
Mobile Home Requirements
 
Outside air must be installed - see "Outside Air Requirements" on page 12
 
Chimney connector and chimney must be one of the following types:
AMERI-TEC model DCC with model HS chimney
DURAVENT model DVL with DURATEC or DURA-PLUS chimney
GSW Super Chimney Twenty-One connected directly to appliance
I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
METALFAB model DW connector with TG chimney
OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
SELKIRK METALBESTOS model DS connector with model SSII chimney
Standard Masonry Chimney with any one of the above listed connectors
NOTE: Reduced clearance connectors may not connect to the flue collar – an appliance adapter may be required.
 
Stove placement must maintain the following clearances to combustibles (drywall, furniture, etc.)
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
A
B
F
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
C
Measure all clearances from the 
nearest edge of the stove top.
D
E
C
Figure 9
Minimum Clearance
(See the illustration above)
Reduced Clearance
Connector
A
Sidewall to stove
15"
B
Backwall to stove
6"
C
Cornerwall to stove
6-1/2"
D
Connector to sidewall
23-1/2"
E
Connector to backwall
8-1/4"
F
Connector to cornerwall
15"
 
If using offsets, use the connector clearance listed in Figure 10,
not the connector manufacturer's clearance.
 
The appliance must be secured to the floor (consult your
building official).  Secure the outside air boot to the floor and
stove to insure the stove does not dislocate.
 
Mobile home installations require a spark arrester at the
chimney termination.
 
The appliance must be grounded to the chassis of the mobile
home (consult your building official).
 
WARNING:DO NOT INSTALL IN SLEEPING ROOM.
 
CAUTION:THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
12” Min.
Connector Clearance 
(as outlined above)
Stove Clearance 
(as outlined above)
Figure 10