Lennox Hearth VINT-DVS-U Manuale Utente

Pagina di 32
13
Vent Parts List
Secure Vent direct­vent pipe by Security Chimneys* may be used with 
this appliance. Please see the lists below to verify the components avail­
able from each direct­vent pipe manufacturer. Snorkel terminations are 
available for applications which may require vertical rise on the building 
exterior. The components listed below come in a galvanized finish. Most 
of the components are also available in a painted black finish. Add a “B” 
to the end of the part number when ordering if a black part is desired.
Security™ Secure Vent 6-5/8”x 4” Pipe
Part Number 
Description
SV4LC   
6” Pipe Length
SV4L12   
12” Pipe Length
SV4L24   
24” Pipe Length
SV4L36   
36” Pipe Length
SV4L48   
48” Pipe Length
SV4LA   
6” Pipe, Adjustable
SV4LA12 12” Pipe, Adjustable
SV4FA   
Flashing, 1/12 to 6/12 Roof Pitch
SV4FB   
Flashing, 7/12 to 12/12 Roof Pitch
SV4RSM   
Wall Radiation Shield
SV4E46   
45º Elbow
SV4E90   
90º Elbow
SV4VS   
Vinyl Shield Protector
SV4FC   
Storm Collar
SV4CGV   
Vertical Termination Cap
SV4BF   
Firestop
SV4CHC   
Horizontal Termination Cap
SV4STC36 
Snorkel Termination Cap (36”)
SV4STC14 
Snorkel Termination Cap (14”)
SV4BM   
Wall Band
Simpson Dura­Vent GS 6­5/8”x 4” Pipe
Part Number 
Description
908 
 
6” Pipe Length
907 
 
9” Pipe Length
906 
 
12” Pipe Length
904 
 
24” Pipe Length
903 
 
36” Pipe Length
902 
 
48” Pipe Length
911 
 
11” to 14­5/8” Pipe, Adjustable
942 
 
Wall Thimble
940 
 
Rnd Support Box/Wall Thimble Cover
941 
 
Cathedral Ceiling Support Box
943 
 
Flashing, 0/12 to 6/12 Roof Pitch
943S 
 
Flashing, 7/12 to 12/12 Roof Pitch
945 
 
45º Elbow
990 
 
90º Elbow
950 
 
Vinyl Siding Standoff
953 
 
Storm Collar
963 
 
Ceiling Firestop
988 
 
Wall Strap
981 
 
Snorkel Termination (36”)
982 
 
Snorkel Termination (14”)
984 
 
Horizontal Termination Cap
985 
 
Horizontal Termination Cap (High Wind)
980 
 
Vertical Termination Cap
991 
 
Vertical Termination Cap (High Wind)
Horizontal Vent Installation
Venting terminals may not be recessed into a wall or siding.
1. Set the unit in the desired location. Check whether or not wall studs 
are in the way when the venting system is attached. If wall studs are 
in the way, you may want to adjust the location of the unit.
2. Any stove that is horizontally terminated and has a vertical section 
of pipe off the top of the stove, that first section of pipe must be a 
minimum of 18” long.
3. All horizontally terminated vent installations may only use 6­5/8”x 4” 
Security™ Secure Vent pipe*.
4. Assemble the desired combination of pipe and elbow(s) to the appli­
ance adapter with pipe seams facing down. Offsetting the pipe seams 
as double seams in one place will cause the outer pipe to take an oval 
shape.
5. When this pipe passes through a wall, a wall thimble ­ Simpson #942 
or Security™ #SV4RSM ­ is required. The hole in the wall for the 
wall thimble should be 9­1/4”x 10­1/4”. If the wall being penetrated 
is constructed of non­combustible material (i.e. masonry block or 
concrete), a 7” diameter hole is acceptable and a wall thimble is not 
required.
6. Horizontal runs of vent pipe must be supported every 3 feet. Wall 
straps ­ Simpson #988 or Security™ #SV4BM ­ are available for this 
purpose.
7. If the vent passes through a ceiling or floor, a firestop ­ Simpson #963 
or  Security™ #SV4BF ­ is required.
8. Also note that venting terminals shall not be recessed into a wall or 
siding. If installing the termination cap on a wall covered with vinyl 
siding, a vinyl siding standoff ­ Simpson #950 or Security™ #SV4VS 
­ or furring strips must be used to ensure that the termination cap is 
not recessed into the siding.
9. The horizontal run of vent should have a 1/4” rise for every 12” of run 
toward the termination. Never allow the vent to run downward. This 
could cause high temperatures and may present the possibility of a 
fire.
10.If the wall being penetrated is constructed of noncombustible material, 
such as masonry block or concrete, an 7” diameter hole is acceptable 
and a wall thimble is not required..
11. The location of the horizontal vent termination on an exterior wall must 
meet all local and national building codes and must not be blocked 
or obstructed. For allowable external vent termination locations (see 
Page 17).
12. Allowable clearances from the vent pipe to combustible materials must 
be maintained. See Page 9 for these clearances.
13. Do not locate the termination cap where it may be blocked by shrub­
bery or snow.
* Other approved chimney brand is Simpson Dura­Vent DV­GS.