INSTALLATION 
 
PAGE 8 
AIR INTAKE COVER 
The pedestal is equipped with an air intake cover (lo-
cated at the top front of the pedestal).  The air intake 
cover should be adjusted to the open position if outside 
combustion air is NOT provided. If outside combustion 
air is provided, adjust to the closed position (see illustra-
tion to the right). 
 
 
OUTSIDE AIR 
In all manufactured (mobile) homes and in many site 
built residences (subject to local code), a stove may be 
required to use outside air for combustion. A 5 ¼” (133 
mm) square outside air floor duct is available through 
your dealer. 
 
 
 
 
 
 
This stove can take in outside air directly through the 
base. This type installation requires a hole through the 
floor protector and the use of outside air floor duct (cata-
log # 14M67) to penetrate into the air space below the 
home. When outside air is hooked up, the Air Intake 
Cover must be adjusted to the closed position (see Air 
Intake Cover
 section on this page). 
 
NOTE:  Because the base sits 1” (25.4 mm) off the floor, 
the outside air floor duct can be positioned along the 
front to rear center line under the pedestal, but as close 
to the opening in the base as location permits.  The air 
duct opening must be protected from any possible ob-
struction including loose floor insulation. 
 
MANUFACTURED (MOBILE) HOME REQUIREMENTS 
This stove is certified as a Room Heater, Solid Fuel Type 
and may be used in Manufactured Housing providing the 
following requirements are followed: 
 
•  An outside air inlet must be provided for combustion 
and be unrestricted while unit is in use.  
•  WARNING:  DO NOT INSTALL IN SLEEPING 
ROOM. 
•  Regulations require that the appliance must be se-
cured to the floor and grounded to the chassis. See 
Securing the Stove to the Floor (and) Grounding 
Stove. 
•  Required venting is 6” (152 mm) diameter Type L-
Vent connector pipe with listed factory-built 103HT 
chimney suitable for use with solid fuels or a code 
approved masonry chimney. Approved brands of fac-
tory built chimney are listed in this manual. A rain 
cap and spark arrestor is required (see Clearances, 
pages 6 & 7). 
•  CAUTION:  THE STRUCTURAL INTEGRITY OF 
THE MOBILE HOME FLOOR, WALL, AND CEIL-
ING/ROOF MUST BE MAINTAINED.
 
•  The chimney must provide for a section joint so that 
any parts extending above 13’ 6” (411 cm) from 
ground level can be removed for transportation of the 
mobile dwelling. 
Air Intake 
Cover
 
Open 
Closed 
Pedestal 
Front
 
Floor Protector 
Stove 
Outside 
Air Floor 
Duct