New Buck Corporation FS 21 Manuale Utente

Pagina di 33
Page 29 
 
 
TROUBLESHOOTING 
 
 
PROBLEM
 
POSSIBLE CAUSE
 
SOLUTION
 
 
 
 
Sluggish Heater
 
Obstruction in chimney
 
Check for and remove 
obstruction
 
 
Wet or unseasoned wood 
being burned. 
Burn dried natural seasoned 
hard wood. 
 
Poor chimney draft 
Improper chimney height or 
wrong size flue is being used.  
Cooler temperatures caused 
by external chimney. 
High Fuel Consumption 
Improper regulation of draft 
or inlet air 
(a)  Close inlet air control as 
much as possible to 
maintain desired heat 
output.   
(b) Check gaskets, reinstall 
fiberglass gasket around 
doors and glass as 
necessary 
 
Improper door fitting 
Check door gasket, check 
adjustment of door latch. 
Backpuffing Gusts 
of 
Wind 
Chimney may need wind 
diverts.  Raise chimney for 
better draft. 
Smoke rolls out when heater 
door is opened. 
Wind gusts blowing down the 
chimney 
Chimney may need wind 
diverts.  Raise chimney for 
better draft. 
 
Opening heater door too fast 
Crack door for 15 seconds 
before fully opening door. 
 
SECTION VII