Lide Glass Lid 3500P Manuale Utente

Pagina di 39
 
35
 
 
 
If the low fire heat setting is too low for the fuel that 
you are burning and the fire goes out, the number 1 or 
2 heat setting can be adjusted through the access hole 
located next to the system indicator light. (2) 
 
If the draft setting is too low on the number 1 or 2-heat 
setting, it can be adjusted through the access hole 
located next to the fuel stirrer knob. (1) 
 
To adjust the settings, place a small screwdriver 
through the hole to the adjustment screws.  Turning the 
screw clockwise increases the draft and 
counterclockwise decreases the draft. (1) Turning the 
screw clockwise decreases the fuel feed rate and 
counterclockwise increases the fuel feed rate. (2) 
 
The systems indicator light will blink showing the 
number that you are on.  There are 10 settings that are 
available with 1 blink being the lowest and 10 blinks 
being the highest.  When you turn the adjustment 
screw to the next setting the light will blink the number 
that you are on and then the light will stay on. 
(Example: If the setting is turned to  # 9 the light will 
blink 9 times and then stay on). 
 
Note: Number 1 on the draft adjustment setting is the 
lowest setting and on the Fuel Feed rate adjustment 
setting it is the highest feed rate.  As you turn the 
adjustment screw clockwise 1 – 2 – 3, etc the draft (1) 
will increase and the fuel feed rate (2) will decrease. 
The normal settings on both should be 1 blinks  
 
THESE SETTINGS NEED TO BE MADE 
BY A QUALIFIED COUNTRYSIDE 
SERVICE TECHNICIAN. 
 
The circuit board fuse is located on the back of the 
board.  If the board does not work, check the fuse to 
make sure that it is good. 
The thermostat hookup is located on the back of the 
circuit board.  See thermostat installation. 
Heat Setting 
Off 
High 
Off 
High 
Fuel Stirrer 
Draft 
Adjustment 
Fuel Feed Rate 
Adjustment
 
SETTING THE CIRCUIT BOARD 
System Indicator 
Light