Heatilator • ECO-ADV-WS22 • 7057-128C • August 13, 2010
 
INSTALLATION: Full Vertical OR Horizontal with 2 foot (609mm) minimum vertical Off Stove Top 
SINGLE WALL PIPE 
10 (254) 8.25 (210)  21 (533)  11 (279)  3.5 (89) 12.5 (318)  49 (1245)     *
DOUBLE WALL PIPE 
9 (229)  7 (178)  19.5 (495)  9 (229)  3 (76)  12 (305)  49 (1245)    10 (254)
INSTALLATION:  90
o
 ELBOW OFF TOP OF STOVE THROUGH BACKWALL
SINGLE WALL PIPE 
9.25 (235) 7.5 (191)  18 (457)  8 (203)  3.5 (89) 12.5 (318)  49 (1245)     *
DOUBLE WALL PIPE 
9.25 (235) 7.5 (191)  18 (457)  8 (203)  3 (76)  12 (305)  49 (1245)    10 (254)
INSTALLATION:  ALCOVE
   
Six  inch  (6")  (152mm)  diameter  listed  Single  Wall  or  Double  Wall  air 
insulated  connector  pipe  with  UL103  HT**  Listed  factory-built  Class  "A"  chimney,  or  a  masonry 
chimney.  (Mobile Home must be equipped with a spark arrestor).  Maximum depth of Alcove shall be 
no  more  than  48  inches  (1219mm)  with  a  minimum  height  of  84  inches    (2133mm)  from  floor  to 
bottom of ceiling and the referenced clearances.
**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650
o
C Factory-built chimney.
 
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
WARNING! Risk of Fire!
•  Comply with all minimum clearanes to combustibles
as specified.
•  Failure to comply may cause house fire.
NOTE:  Service Space
In order to replace the tube channel assembly a clearance
of 19 inches (483mm) is required on the right side of stove
in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-
nected from the chimney to proceed with the tube replace-
ment.
B. Clearances to Combustibles (UL and ULC)
NOTE:  Clearances may only be reduced by means 
approved by the regulatory authority having jurisdiction
G
A
B
ALCOVE SIDE VIEW
E
F
E
F
CORNER INSTALLATION
G
H
90° OFF TOP 
UP & OUT CEILING 
CLEARANCE
STOVE TO CEILING 
CLEARANCE 
C
D
ALCOVE TOP VIEW
A
B
C
D
BACKWALL / SIDEWALL
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS:  Inches & (Millimeters)
NOTE:  All “A”, “C” and “F” dimensions are to inside diameter of flue collar.