Monessen Hearth SS38 Manuale Utente

Pagina di 40
46D0232
22
SS38 Direct Vent Gas Stove
1.  Check gas type. The gas supply must be the same as 
stated on the appliance’s rating decal. If the gas supply 
is  different  from  the  stove,  STOP!  Do  not  install  the 
appliance. Contact your dealer immediately.
2.  To ease installation, a 30" (mm) flex line with manual 
shut-off valve has been provided with on this appliance. 
Install and attach 1/2" gas line onto shut-off valve. 
3.  After  completing  gas  line  connection,  purge  air 
from gas line and test all gas joints from the gas 
meter to the stove for leaks. Use a soap and water 
solution or a gas sniffer. 
4.  To adjust flame height, turn HI/LO knob to HI to get 
maximum pressure to burner. Turn HI/LO knob to 
LO to get minimum pressure. 
5.  To  check  gas  pressures  at  valve,  turn  captured 
screw counter clockwise 2 or 3 turns and then place 
tubing to pressure gauge over test point. Turn unit 
to high. Figure 29. After taking pressure reading, 
be sure and turn captured screw clockwise firmly 
to reseal. Do not over torque. Check test points for 
gas leaks with a soap and water solution. 
INSTALLING LOUVERS 
Attach the top louver unit (two louvers 
and two louver brackets) to stove with 
four (4) screws provided — two (2) on 
each side. Figure 30. Repeat for bottom 
louver unit. 
STOVE INSTALLATION
FP1979
Millivolt gas valve
FP1979
Figure 29 - 
Gas Pressure Check at Gas Valve 
Pressure 
Test “IN”
Pressure 
Test “OUT”
HI/LO Knob
Pilot Adjustment Screw 
W
ARNING
Do  not  use  open  flame  to  check  for  gas 
leaks.
ST1113
install louvers
Louvers
Louver Bracket 
Screws
Louver 
Bracket 
Figure 30 - 
Installing Louvers 
ST1113