es
Residential Close Clearance 
(To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required 
from the stove collar to the ceiling level.
Unit
From Unit
From Corner
From Vent 
centerline
F1100 
    A               B
C               D
E               F
with Airmate
    9”              5”                  
  3”              21”             
11.5”          15”
with Rear Defl ector
  13.5”           5”  
   5”            25.5” 
11.5”          17”
Mobile Home Close Clearance 
(To be installed with required pipe components)
“C” Vent single wall pipe is not approved for Mobile Home installations. (Refer to mobile home instructions.)
Unit
From Unit
From Corner
From Vent 
centerline
F1100
    A               B
C               D
E               F
with Airmate
   11”             6”                  
  6”              23”             
12.5”          18”
with Rear Defl ector
   13”             5”  
  9”              25” 
11.5”          21”
Unit
From Unit
From Vent 
centerline
Min. 
Width
Min. Hearth 
to Rear Wall
F1100
    G               H
I               J
K
L
with Airmate
   11”             7”                  
  23”         13.5”             46”
39”
with Rear Defl ector
   13”            5”  
  25”         11.5” 
50”
37”
Minimum Alcove Clearance To
Combustible Materials
Regency Freestanding models have been alcove approved and must be 
installed with a listed double wall connector to the ceiling level. 
Note:  Minimum alcove ceiling height - 84"
 
 
Maximum depth of alcove - 36"
*The rear clearance to combustibles is less than 6" (152mm), for corner 
installations the rear corners may be angled to take advantage of the
closer clearances.
NOTE: In Canada, fl oor protection must extend 18" to the front 
and 8" to each side of the stove.
Floor Protection
A combustible fl oor must be protected by a non-combustible material 
(like tile, concrete board, or certifi ed to UL-1618 or as defi ned by local 
codes) extending beneath the heater and a minimum of 6" from each 
side and minimum 16" from the front face of the stove and minimum 6" 
(or the rear clearance to combustibles whichever is smaller) from the 
rear of the stove. 
    Minimum Overall Width (X) of Floor 
       Protector
 for all installations: 
Small Stove 
F1100S 
36"
Minimum Overall Depth (Y) of Floor Protector
Unit
Residential
“C” Vent
Residential 
Close 
Clearance
Mobile 
Home Close 
Clearance
Alcove
F1100
    Y               Z
Y               Z
Y               Z
Y               Z
with Airmate
   38”             6”                  
  37”*           5”             
38”           6”    
38”           6”
with Rear Defl ector
   38”             6”  
  37”*           5”    
37”*          5”    
37”*          5”    
F1100 Wood Stove