Regency F37-NG Manuale Utente

Pagina di 28
12
F37 Regency
®
 Rear Flued Room Sealed Freestanding Gas Heater
System Data - F37
Burner Inlet Orifi ce Sizes:
                 
        NG  LPG
  Burner   
#37 
#52
               
Max. Input Rating 
31.7 mj
Min. Input Rating 
16 mj
         
Supply Pressure 
 NG 
min. 
1.13kPa
 LPG 
min. 
2.75kPa
Manifold Pressure
 NG 
.89 
kPa 
 LPG 
2.55 
kPa
GAS CONNECTION
The gas connection is a 1/2" NPT Male 
Thread.   Copper can be used or other con-
nections approved by AG 604.
When using copper or fl ex connectors use only 
approved fi ttings. Always provide a union so 
that gas lines can be easily disconnected for 
burner and/or valve servicing. Flare nuts for 
copper lines are  usually considered to meet 
this requirement.
Important: Always check for gas leaks with a 
soap and water solution or gas leak detector. 
Do not use open fl ame for leak testing.
Note:  Prior to any pressure testing of 
the gas supply piping system 
that exceeds test pressures of 
3.45 kPa, this appliance must 
be disconnected from the pip-
ing system.  If test pressures 
equal to or less than 3.45 kPa 
are used then this appliance 
must be isolated from the piping 
system by closing its individual 
manual shut-off valve during the 
testing.
VERTICAL TERMINATION WITH 
CO-LINEAR FLEX SYSTEM
THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING 
A SEPARATE SOLID FUEL BURNING APPLIANCE.
This appliance is designed to be attached to two 3" (76mm) co-linear aluminium fl ex running the 
full length of the chimney. See the Flueing Arrangements chart in the "Flue Arrangement" sec-
tion for minimum and maximum  fl ue lengths. See chart  below for minimum distances from roof. 
Periodically check that the fl ue is unrestricted.
Masonry chimneys may take various contours which the fl exible liner will accommodate. However, 
keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must  be attached to the inlet air collar of the termination cap.
Required Parts:
Part # 
Description
946-529 
Co-linear DV Vertical Termination Cap
948-305 
3" Flex - 35 ft.
640-994 F37 
Dura-Vent 
Adapter
946-563 
Co-Axial to Co-Linear Adapter Kit
 
which contains the following: 
 Co-linear 
Flex 
Adapter 
(270-585) 
 Outer 
Pipe 
(946-257)
 Inner 
Pipe 
Adapter 
(946-219)
Approved Caps
980 Vertical 
Termination 
Cap
923GK 3" 
Co-linear 
Adapter 
 with 
fl 
ashing
INSTALLATION