Handle glass assembly with care.
CAUTION
•  Inspect the gasket to ensure it is undamaged.
•  Inspect the glass for cracks, chips or 
scratches.
•  Do NOT strike, slam or scratch glass.
•  Do NOT operate appliance with glass door 
removed, cracked, broken or scratched.
•  Replace glass assembly as a complete 
assembly.
I.  Glass Door Assembly
Figure 8.15
  Turn the appliance OFF and let it cool down before 
replacing the inner glass door assembly.
Remove the glass door assembly by opening latches at the 
bottom front of the appliance, on both the left and right sides. 
Lift out and away from the appliance.
Replace with a new glass door assembly.
NOTE:  The glass, gasketing, and frame must be replaced 
as a complete unit as supplied by the manufacturer.
Do NOT use substitute material. 
J.  Blower Installation
TOOLS REQUIRED:  #2 Phillips head bit; hand drill; 11/16 
in. wrench; and a 5/16 in. wrench.
Snap disc
through bracket
5/16" nut
FROM THE KIT YOU WILL NEED: Blower motor; wire 
harness; rheostat; rheostat nut; knob; screws; and 1 zip-tie.
FROM THE STOVE COMPONENT BAG YOU WILL 
NEED:
 snap disc bracket and 5/16 in. nut.
Figure 8.16   
Turn off gas supply (if gas is connected), and 
remove the rear shield.  Remove the blower from packaging. 
Place the blower under the  appliance.  Attach the blower 
from the front with four screws to the blower bracket.
Figure 8.17   
Install the snap disc in the bracket.  Attach the 
bracket to the fi rebox with a 5/16 in. wrench.
Figure 8.18   
Connect the electrical connector to the snap 
disc.