5
INSTALLATION  AND  REPAIRS
SHOULD BE DONE BY AN AUTHOR-
IZED SERVICE PERSON. THIS AP-
PLIANCE SHOULD BE INSTALLED,
REPAIRED, INSPECTED BEFORE
USE AND AT LEAST ANNUALLY
BY AN AUTHORIZED SERVICE PER-
SON.  MORE FREQUENT CLEAN-
ING MAY BE REQUIRED DUE TO
EXCESSIVE LINT FROM CARPET-
ING, ETC.  IT IS IMPERATIVE THAT
THE CONTROL COMPARTMENT,
BURNERS AND CIRCULATING AIR
PASSAGEWAYS OF THE APPLI-
ANCE BE KEPT CLEAN.
IMPORTANT:
SAVE  THESE
INSTRUCTIONS
The REGENCY Rear Flued Room Sealed Free-
standing Gas Stove must be installed in accord-
ance  AG601  and  NZS  5261  and  with  these
instructions. Carefully read all the instructions
in this manual first. Consult the building authority
having jurisdiction to determine the need for a
permit prior to starting the installation.
Note: Failure  to  follow  the  instructions
could  cause  a  malfunction  of  the
heater which could result in death,
serious  bodily  injury,  and/or  prop-
erty damage.  Failure to follow these
instructions  may  also  void  your
fire  insurance  and/or  warranty.
SPECIFICATIONS
Fuels:
FG37-NG  is  approved  for  use  with
NG.
FG37-LPG is approved for use with
liquefied petroleum gases (LPG).
Electrical: 240 V   A.C. system.
Circulation Fan:  Two Speed
Log Sets:  Ceramic fibre, 7 per set.
Flue  System:
Axial  (6-5/8"  (168mm)  outer  /  4"
(102mm)  inner  liner)  rigid  flue  and
Riser Vent Terminal.
BEFORE  YOU  START
Safe installation and operation of this appliance
requires common sense, however, please  be
aware  of  the  following:
INSTALLATION
4) We recommend that you plan your installa-
tion on paper using exact measurements
for clearances and floor protection before
actually installing this appliance.  Have an
authorized  building  inspector  review  your
plans before installation.
GENERAL  SAFETY
INFORMATION
1) The appliance shall be installed in accord-
ance  with  the  manufacturer's  installation
instructions,  local  gas  fitting  regulations,
municipal building codes, water supply reg-
ulations, electrical wiring regulations, with
AS5601-2004 (AGA gas installation code)
NZS 5261 (New Zealand)
2) Installation and repair should be done
ONLY  by  an  authorised  person.
3) DO NOT CONNECT TO MASONARY FLUE.
4) This  appliance  must  be  connected  to
the  specified  flue  and  termination  cap
to  the  outside  of  the  building  enve-
lope.  Never  flue  to  another  room  or
inside  a  building.  Make  sure  that  the
flue  is  fitted  as  per  Flueing  instruc-
tions.
5) Inspect  the  flueing  system  annually  for
blockage and any signs of deterioration.
6) Flueing terminals shall not be recessed into
a wall or siding.
7) Any  safety  glass  removed  for  servicing
must  be  replaced  prior  to  operating  the
appliance.
8) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fireplace.
9) Wear  gloves  and  safety  glasses  for  pro-
tection while doing required maintenance.
10) Be  aware  of  electrical  wiring  locations  in
walls  and  ceilings  when  cutting  holes  for
termination.
11) Under no circumstances should this appli-
ance  be  modified.  Parts  that  have  to  be
removed for servicing should be replaced
prior to operating this appliance.
12) Installation and any repairs to this appliance
should be done by an authorised service
person.  An  authorised  service  person
should be called to inspect this appliance
annually. Make it a practice to have all of
your gas appliances checked annually.
13) Do not slam shut or strike the glass door.
DUE  TO  HIGH  TEMPERATURES,
THE APPLIANCE SHOULD BE LO-
CATED  OUT  OF  TRAFFIC  AND
AWAY  FROM  FURNITURE  AND
DRAPERIES.
WARNING: FAILURE TO INSTALL
THIS  APPLIANCE  CORRECTLY
WILL VOID YOUR WARRANTY AND
MAY CAUSE A SERIOUS HOUSE
FIRE.
CHILDREN AND ADULTS SHOULD
BE ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES,
ESPECIALLY  THE  FIREPLACE
GLASS, AND SHOULD STAY AWAY
TO AVOID BURNS OR CLOTHING
IGNITION.
YOUNG  CHILDREN  SHOULD  BE
CAREFULLY  SUPERVISED WHEN
THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.
1) Provide  adequate  clearances  for  servic-
ing,  proper  operation  and  around  the  air
openings into the combustion chamber.
2) The appliance must be installed on a flat,
solid, continuous surface (e.g. wood, met-
al, concrete). This may be the floor, or it can
be raised up on a platform to enhance its
visual  impact.  The  appliance  may  be  in-
stalled on carpeting, tile, wood flooring or
other  combustible  material,  because  the
appliance's  metal  pedestal  base  extends
the full width and depth of the appliance.
The REGENCY Rear Flued Room Sealed
Freestanding Gas Stove can be installed in
a  wide  variety  of  ways  and  will  fit  nearly
any  room  layout.  It  may  be  installed  in  a
recessed position, framed out into the room,
or  across  a  corner.
3) The REGENCY Rear Flued Room Sealed
Freestanding  Gas  Stove  is  approved  for
manufactured home installations, see pag-
es 6 to 9 for the required flue arrangements.
If installed into a manufactured home the
unit must be bolted down to the floor.