E33 FPI Direct Vent Gas Insert
14) Install optional Excalibur Surround. See 
page 15.
15) Install optional remote control or wall ther-
mostat, pages 17.
16) Final check (page 18): Before leaving this 
unit with the customer, the installer must 
ensure that the appliance is fi ring correctly. 
This includes:
 
a) 
Clocking the appliance  to ensure the 
correct fi ring rate.
 
b) 
Adjusting the primary air, if required, 
to ensure that the fl ame does not 
carbon.  See page 9.
 
c) 
Ensuring that the appliance is venting 
correctly.
MATERIALS 
REQUIRED
No electrical power supply is required for the gas 
control to operate.  A 120 Volt AC power cord is 
hooked up to the fan.  Plug the 3 wire cord into 
a suitable receptacle.  Do not cut the ground 
terminal off under any circumstances.
  When 
connected with 120 volts, the appliance must 
be electrically grounded in accordance with 
local codes, current version of the Canadian 
Electrical Code CSA C22.1 (in Canada) or in 
the absence of local codes, with the National 
Electrical Code ANSI/NFPA 70.
NOTE:    This unit is equipped with a heat 
sensor  thermodisc which will prevent the 
blower from operating until the unit reaches 
the correct temperature.
INSTALLATION
11) Due to high temperatures, the appliance 
should be located out of high traffi c areas 
and away from furniture and draperies. 
Children and adults should be alerted to 
the hazards of high surface temperatures, 
especially the fi replace glass, and should 
stay away to avoid burns or clothing ignition. 
Young children should be carefully  super-
vised when they are in the same room as 
the appliance. Clothing or other fl ammable 
material should not be placed on or near 
the appliance.
INSTALLATION 
CHECKLIST
Before installing vent system ensure that the 
damper plate is open and secure to prevent 
the damper plate from falling down and crush-
ing the liner.
The FPI Gas Insert is installed as listed 
below. 
1)  Check all clearances to combustibles, see 
page 7.
2)  Make the gas connection. See page 8.
3)  Install the 3" fl ue liner to the sliding connector 
plate. See page 8.
4)  Slide the unit half way into the fi replace.
5)  Pull the vent connector plate through the 
tapered brackets and fasten to the front 
plate. See page 8.
6)  Slide the unit fully into the fi replace. 
7)  Test gas pressure, page 9. Check aeration 
system, page 9.
8)  Install the optional brick panels. See page 
9.
9)  Install the log set. See page 10.
10)  Assemble and install the faceplate and trim. 
See page 13.
11) Install the standard fl ush door. See 
 page 
14.
12) Install both louvers. See page 14.
13) Install optional full screen doors. See page 
16.
MINIMUM FIREPLACE 
OPENING
The minimum fi replace opening for the FPI 
gas fi replace insert is shown in the following 
diagrams:
WARNING: 
Electrical Grounding Instructions
This appliance is equipped with 
a three pronged (grounding) plug 
for your protection against shock 
hazard and should be plugged 
directly into a properly grounded 
three-prong receptacle. Do not cut 
or remove the grounding prong 
from this plug.
NOTE: If you are installing the Excali-
bur, the minimum fi replace dimensions 
are as follows:
Width (at front): 
34-1/2" (876mm)
Depth: 17-3/4" 
(451mm)
Height: 
26"       (660mm)
MINIMUM FIREPLACE 
OPENING EXCALIBUR 
OPTION
The minimum fi replace opening for the FPI 
gas fi replace insert is shown in the following 
diagrams:
Emissions from burning wood or gas could 
contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects or other 
reproductive harm.