c.  Assemble the crevice tool from the micro cleaning kit to 
attach to a Shop Vac.  Figure 38.1.
d.  Use the crevice tool to fi nish cleaning the heat exchanger 
fi ns.   It is critical that the 2 exhaust exits at the back of the 
fi rebox fl oor (left and right) be thoroughly cleaned.  Figure 
38.2.
  There are several ways this can done.
 
1.  Use the crevice tool.
  2.  Attach  a  hose  1/2  inch  (12.7mm)  in  diameter  and 
approximately 2 feet (607mm  in length to your vacuum 
hose.
  3.  Use  a  bottle  brush  and  push  the  ash  down  to  the 
bottom.  Remove the combustion (exhaust)  blower 
and then vacuum out the ash.  
2 exhaust exits (left and right side) must 
be thoroughly cleaned.  Each exit is 
approximately 4 inches wide, 1 inch 
across and 3 inches deep.
Figure 38.2
Figure 38.1
NOTE  It is normal to see a certain amount of wear of the 
heat  exchanger  fi ns.    You  may  notice  some  fl aking  and 
pitting  on  some  of  the  pins.   The  heat  exchanger  system 
will function as designed with as many as 15 of these pins 
missing.
Loosen all 6 nuts, but do NOT Remove
f. Removing the Combustion (Exhaust) Blower
1.  The combustion blower is mounted in the bottom 
right rear of the appliance.  Figure 38.3.
2.  Remove side panel and then using an 11/32 nut 
driver to loosen all six nuts, but do not remove.  
Rotate the blower and remove from the housing. 
Figure 38.4.
3.  Set the blower on the fl oor of the appliance.  You do 
not need to disconnect the wires.  
4.  Vacuum out the exhaust area.  Figure 38.5.
Figure 38.3
Figure 38.4
Combustion Blower
Vacuum out the exhaust area.