Mt. Vernon Pellet Insert (AE)
Convection Blower Replacement
G.  Convection Blower Replacement (Cont’d)
1.  After  the  sides  are  removed,  reach  behind  the  blower 
and  release  the  latch  by  pushing  the  top  of  the  latch 
towards the blower.  Figure 42.1.
2.  Rock the top of the blower slightly and lift up and out.  
The blower will pass around the control board and out 
the side of the appliance.
3.  Disconnect  the  wire  harness  from  the  bottom  of  the 
blower by depressing the tabs on the sides of the con-
nector and then pulling to remove.  Figure 42.2.
4.  Re-connect  wire  harness  to  the  new  replacement 
blower.  Install the blower by placing the bottom fl ange 
into  the  opening  fi rst  then  rotate  blower  up  into  posi-
tion.  
5.  When the blower is properly positioned the latch will engage 
the notch to hold the blower in place.  Figure 42.3.
Convection 
Blower
Disconnect Wire Harness 
from Bottom of Blower
Notch
Latch
Latch Engaged
Figure 42.2
Figure 42.1
Figure 42.3