Desa S26PTA Manuale Utente

Pagina di 28
www.desatech.com
110361-01G
15
Figure 20 - Pilot
Thermocouple
Pilot Burner
Ignitor Electrode
OPERATING hEATER
Continued
INSPEcTING BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT FLAME PATTERN
Figure 21 shows a correct pilot flame pattern. Figure 
22 shows an incorrect pilot flame pattern. The incor-
rect pilot flame is not touching the thermocouple. 
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise 
 to the OFF 
position.
Shutting Off Burners Only (pilot stays lit)
Turn  control  knob  clockwise 
  to  the 
PILOT position.
THERMOSTAT CONTROL 
OPERATION
The thermostat control knob can be set to any 
comfort level between HI and LO. The ther-
mostat will gradually modulate the heat output 
and flame height from higher to lower settings 
or pilot, in order to maintain the comfort level 
you select. The ideal comfort setting will vary 
by household depending upon the amount of 
space to be heated, the output of the central 
heating system, etc.
Note:
 Selecting the HI setting with the control 
knob will cause the burners to remain fully on, 
without modulating down in most cases.
MANUAL LIGHTING 
PROCEDURE
1.  Follow steps 1 through 5 under Lighting 
Instructions, page 14.
2.  Depress control knob and light pilot with 
match. 
3.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob. Now follow step 8 Lighting 
Instructions, page 14
This will cause the thermocouple to cool. When the 
thermocouple cools, the heater will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 22
•  turn heater off (see To Turn Off Gas to Appliance)
•  see Troubleshooting, page 18
Note:
 The correct pilot flame on natural gas units 
will have a slight curve, but flame should be blue 
an have no yellow or orange color.
Figure 21 - Correct Pilot Flame Pattern 
(Natural Gas Shown) 
Figure 22 - Incorrect Pilot Flame Pattern 
(Natural Gas Shown) 
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
Figure 23 - Correct Flame Pattern with 
Control Knob Set to High Flame
Figure 24 - Incorrect Flame Pattern with 
Control Knob Set to High Flame
Approx. 
3-6" 
Above 
Top of 
Logs
More 
Than 8" 
Above 
Top of 
Logs
BURNER FLAME PATTERN
Figure 23 shows a correct burner flame pattern. 
Figure 24 shows an incorrect burner flame pattern. 
If burner flame pattern is incorrect,
•  turn heater off (see To Turn Off Gas to Appliance)
•  see Troubleshooting, page 18