Desa S26PTA Manuale Utente

Pagina di 28
www.desatech.com
110361-01G
18
TROUBLEShOOTING
 WARNING: Turn off heater and let cool before servicing. Only a 
qualified service person should service and repair heater.
 CAUTION: Never use a wire, needle or similar object to clean 
ODS/pilot. This can damage ODS/pilot unit.
Note:
 All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. Ignitor  electrode  not  con-
nected to ignitor cable
2. Ignitor cable pinched or wet
3. Piezo ignitor nut is loose
4. Broken ignitor cable
5. Bad piezo ignitor
6. Ignitor electrode broken
7. Ignitor electrode positioned 
wrong
1. Gas supply turned off or equip-
ment shutoff valve closed
2. Control knob not in PILOT 
position
3. Control knob not pressed in 
while in PILOT position
4. Air  in  gas  lines  when  in-
stalled
5. Depleted gas supply, propane/
LP only
6. ODS/pilot is clogged
7. Gas regulator setting is not 
correct
REMEDY 
1. Reconnect ignitor cable
2. Free ignitor cable if pinched 
by any metal or tubing. Keep 
ignitor cable dry
3. Tighten  nut  holding  piezo 
ignitor to base panel of log 
set. Nut is located behind base 
panel
4. Replace ignitor cable
5. Replace piezo ignitor 
6. Replace pilot assembly
7. Replace pilot assembly
1. Turn on gas supply or open 
equipment shutoff valve
2. Turn control knob to PILOT 
position
3. Press in control knob while in 
PILOT position
4. Continue holding down con-
trol knob. Repeat igniting op-
eration until air is removed
5. Contact local propane/LP gas 
company
6. Clean ODS/pilot (see Clean-
ing  and  Maintenance,  page 
16) or replace ODS/pilot as-
sembly
7. Replace gas control
OBSERVED PROBLEM
When ignitor button is pressed, 
there is no spark at ODS/pilot
When ignitor button is pressed, 
there is spark at ODS/pilot but 
no ignition