Country Flame DV 30 Manuale Utente

Pagina di 48
 
A certified service technician will require one of the following Country Flame certified conversion kits, 
depending on the type of conversion being planned. 
 
PROPANE CONVERSION KIT 
To convert from natural gas to propane fuel follow conversion Steps 1 through 15 starting on this page, 
using one of the following conversion kits: 
Bayvue DV-46N to DV46P Kit BV-4604 
Bayvue DV-30N to DV46P Kit BV-3004 
 
NATURAL GAS CONVERSION KIT 
To convert from propane to natural gas fuel follow conversion Steps 1 through 15 starting on this page, 
using one of the following conversion kits: 
Bayvue DV46P to DV46N Kit BV-4603 
Bayvue DV30P to DV46N Kit BV-3003 
 
PROPANE CONVERSION  
Bayvue DV appliances are shipped from the Country Flame factory set for 46,000 Btu Natural Gas fuel 
usage; however, conversion kits may be purcahsed from Country Flame to convert the Bayvue DV to 
different fuels (propane or natural gas) or lower the heat outuput to 30,000 Btu.  Depending on the specific 
model owned and being converted, conversion kits contain different repalcement parts that are kit specific.  
Conversion requires adjustment to the regulators, the burners, and the pilot system.  Refer to TABLE 1 and 
page 4 and page 5 for the correct gas pressures corresponding to the conversion kit being used. 
 
 
WARNING:
 This conversion kit shall be installed by a qualified service agency in accordance 
with the manufacturer’s instructions and all applicable codes and requirements of the 
authorized agency having juristriction.  If the information in these instructions are not followed 
exactly, a fire, explosion or production of carbon monoxide may result causing property damage, 
personal injury or loss of life.  The qualified service agency is responsible for the proper 
installation of this kit.  The installation is not proper and complete until the operation of the 
converted appliance is checked as specified in the owner instructions supplied with the kit. 
 
STEP 1 
Turn the control knob to the OFF position and turn off the gas supply to the valve. 
STEP 2 
Remove control knob extentions from the valve.  Allow system to cool before proceeding. 
STEP 3 
Remove the control panel by removing the two screws located at the top of the panel.  
Disconnect the wire from back of piezoelectric igniter.  Disconnect wires from on/off switch 
and variable speed control if required.  
STEP 4 
Refer to FIGURE 8 and using a Torx T20 screwdriver, remove and discard the three pressure 
regulator mounting screws (Item A), the pressure regulator tower (Item B), and the diaphragm 
assembly (Item C). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 8:  SIT 820 NOVA mV GAS CONTROL VALVE 
Version 1.0h 
15