Enviro C-11112 Manuale Utente

Pagina di 14
Operating Instructions
C
ONTROL
 B
OARD
 F
UNCTIONS
:
1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim 
button until the number 1 and 5 lights appear on the Heat Level Indicator.  This will increase the feed 
rate to four (4) seconds ON time per Auger pulse. This is done only on LOW to allow the burning of 
poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On 
time to two (2) second. This setting is for high-grade fuel only.  Push the button until just the number 
1 light is on, this is for a three (3) second on time (standard setting).
2. AUGER PULSE LIGHT: This light will flash in conjunction with the auger.
MANUAL FEED
ON/OFF
HEAT LEVEL
2
1
7
5
4
3
3. MANUAL  AUGER  FEED:  If  the  unit  runs  out  of  fuel,  this 
button can be used to “prime the auger system”. This button 
will turn off after 60 seconds and then must be released and 
pressed again.
4. SYSTEM LIGHT: Responsible for signaling the state of the 
control board. When the light is flashing during start-up, the 
stove is in an automatic start mode. When the light is solid, 
the Heat Level Setting can be altered.
5. ON/OFF BUTTON: Used to turn the unit ON and OFF.
6. HEAT  OUTPUT  INDICATOR:  Shows  the  present  heat 
output setting.
7. HEAT  LEVEL  ADJUSTMENT:  When  pressed,  the  heat 
output setting of the unit will change from low to high.
Notes: 
• The convection blower speed will vary automatically with the 
feed rate.
• Due to varying fuel qualities this pellet stove may not operate 
on lower Heat Level settings. If your unit goes out when on a 
low setting move the heat level up to a higher setting.
• The lowest and highest heat levels on this pellet stove are 
Figure 3: Circuit Board Control Panel Decal.
Auger Trim
Auger Trim
Auger Trim
2 Seconds
"ON"
3 Seconds
"ON"
Factory Setting
4 Seconds
"ON"
1
1
1
4
5
Figure 4: Auger trim  and heat level indicator. 
used for adjusting and accommodating 
for different pellet sizes and the varying 
energy produced by the fuels. The size 
of the pellets will change the volume of 
fuel being fed. 
•  The  unit  should  be  run  at  a  setting 
where the least amount of cleaning of 
the burn pot is needed.
8