Hans Grohe Installation / Warranty Starck X Istruzioni Di Montaggio

Pagina di 8
Prepare to install the faucet:
This faucet requires 2 1/2” female threaded fittings, 3 1/8” apart (on center) for the hot and cold
supplies.  For proper operation of the faucet, the hot supply should be to the left, the cold to the right.
These should be recessed 3/8” behind the surface of the finished wall.
Finish and seal the wall before installing the faucet.
Your local plumbing codes may require supply stops for the hot and cold water supplies.  These should
be installed in an easily accessible location.
Know and follow all applicable plumbing codes regarding the air gap between the end of the spout
and the flood level of the sink.
No drain is included with this faucet.  Contact the manuacturer of your specific lavatory for
recommendations regarding a suitable drain.
Install the faucet:
Seal the wall with a compatible, waterproof bathroom
sealant.
Wrap the threads on the offset adapters with several
layers of Teflon
TM
 tape.  Install them to the hot and cold
supplies.